Page 32
Milltronics SF 500 – INSTRUCTION MANUAL
7ML19985CN01
mmmm
m
Recalibr
at
ion
Press
Press
if % change is negative, remember to enter the minus sign, e.g. -1.3
Material Test
The Material Test option allows the SF 500 to calculate the size of the material sample as
recorded by its totalizers and allows the operator to directly enter the actual weight of the
material sample. The % error is calculated and can be accepted or rejected by the
operator.
Access P019 and enter EDIT mode
Press
Press
Press
Press
Press
P598 Span Adjust Percentage
E
Enter Calc/- error
0.00
P017 Test Rate Weight: MS1
V
Enter Test Rate
56.78
P019 Manual Span Adjust
E
Select 1-% Change 2-Material Test
0
Material Test
Add to Totalizer 0-No, 1-Yes
Material Test
Press ENTER to start
Material Test
#.###
Press ENTER key to stop
Material Test
964.032
Enter actual amount
Material Test Deviation
-1.19
Accept 0-No, 1-Yes:
e.g. the new test rate value is displayed
if yes, the weight of the material test will be
added to the totalizer, if no, material is
added to test totalizer (4) only.
e.g. do not add weight of material test
to totalizer
the totalizer reading as the material test
is run
e.g. the weight totalized by the solids
flowmeter and SF 500
e.g. 975.633 kg is the actual weight of
the material test
e.g. the calculated deviation is
displayed as a % of the actual weight