Description

3-6

6ZB5 430–0BH02–1AA0       

 Siemens AG 1996 All Rights Reserved 

SINUMERIK 805SM / 840C (BS) 

((Einstellung des Adress.....etc. = wie S. 2.2, bitte übernehmen))

((Block 3))

Note

Address space of, for example, 4 bytes means that 4 input bytes and 4 output
bytes are available with the same base address.

((letzte Abschnitt wie S. 2.2, bitte übernehmen))

((S. 2–11))

Note:

The switches not required for 8, 16 and 32–bte address ranges are irrelevant
and any setting is permissible

((Rest der S. genau wie S. 2–3, bitten übernehmen))

((S. 2–12))

((genau wie S. 2–4, bitte übernehmen))

((S. 2–13))

Danger
An incorrect setting of the base address (e.g. dual address assignment or ad-
dress conflict with other I/O modules) results in ”wrong signal states” and can
cause an undefined behaviour of the control and the machine!

Switch S4.2

This switch must always be closed.

I/O ranges

In assigning the slaves, please note that different I/O ranges are available on
the SIROTEC ACR 20, SINUMERIK 805SM and SINUMERIK 840C control-
lers (see Section 2.1.1):

((S. 2–14))

2.2.2 

Elements on the front plate

((ganze S. bis auf letzter Absatz wie alte Vorlage S. 2–5, aber mit den gelb
markierten Änderungen in wie in neue Vorlage S. 2–14 angegeben))

Interface for slave

Via the interface X111 (SUB–D, socket, 9–way), the slave is connected to the
SINEC L2–DP field bus.

((S. 2–15))

Note

TO connect up to the SINEC L2–DP field bus, the bus connectors with the
following order numbers are required:

Order number

Designation

SINEC L2 bus connector (degree of protection IP 20, without heavy–duty
thread socket)

SINEC L2 bus connector (degree of protection IP 20, with heavy–duty thread
socket)

Содержание IM 328-N

Страница 1: ...SINUMERIK 805SM 840C Link to SINEC L2 DP with IM 328 N Module Description 07 96 Edition Manufacturer Documentation ...

Страница 2: ...07 96 Edition SINUMERIK 805SM 840C Link to SINEC L2 DP with IM 328 N Module Description Manufacturer Documentation General 1 Hardware 2 Configuring the Modules 3 Abbreviations A References B Index C ...

Страница 3: ...ntents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Siemens AG 1996 All rights reserved Other functions not described in this documentation might be executable in the control This does not however represent an obligation to supply such functions w...

Страница 4: ...istributed I O System is to be found in Reference 1 ET 200 Distributed I O System Manual For the distributed I O systems ET 200U ET 200B and ET 200C etc the following separate manuals are available Reference 2 Distributed I O System Manual This description contains the information required for start up and service A page for your corrections and suggestions is provided at the end of this manual Pl...

Страница 5: ...portant information to which the reader must pay special attention Important This symbol appears in documents wherever important information is given Ordering data option This symbol indicates functions for which an ordering data option is required options The function described can only be executed if the option designa ted is present ...

Страница 6: ...ffixed to the product itself are persons who for instance Have received training or instruction and authorization to energize and de energize ground and tag electric circuits and equipment in accor dance with established safety practices Have received training or instruction in accordance with established safety practices in the care use and repair of appropriate safety equipment Have received tra...

Страница 7: ...indicated are not taken Caution indicates that personal injury or property damage can result if proper pre cautions are not taken Warning indicates that death severe personal injury or substantial property damage can result if proper precautions are not taken Intended use The device system or system component must be used only for the applications specified in the Catalog and Reference Manual and ...

Страница 8: ...tive and passive faults can be dangerous faults In the case of a drive control for example active faults are ge nerally dangerous because they lead to unauthorized startup of the drive On the other hand a passive fault can result in a dangerous operating state not being reported to the operator This differentiation between possible faults and their task related classifi cation as dangerous and non...

Страница 9: ... 328 N Slave MLFB 6FC5 012 0CA01 0AA0 IM 328 N old and IM 329 N Slave MLFB 6FC5 012 0CA02 0AA0 master and slave have different applications as follows Table 1 1 Different applications between IM 328 N and IM329 N Module Use as IM 328 N 0CA03 IM 328 N 0CA01 IM 329 N Slave 0CA02 Slave for SINEC L2 DP to V3 x X X Slave for SINEC L2 DP PROFIBUS DP acc to DIN E 19245 part 3 X X Master X For information...

Страница 10: ...00 parameterization software 3 2 3 2 Description of the DP standard slaves 3 5 3 2 1 Notes on parameterization of the slaves 3 5 3 2 2 Configuration example for slave 3 7 3 2 3 Procedure for Installation and Startup 3 8 3 2 4 Example of Application 3 9 3 2 5 Status display messages 3 14 3 2 6 Diagnostics functions in the S5 program of the master 3 16 3 3 Description of the L2 DP slave up to V3 x 3...

Страница 11: ... The system is based on the PROFIBUS DP communications standard DIN E 19245 Part 3 and works on the master slave principle The following devices can be master stations ÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉ SIMATIC S5 115U 135U 155U with IM 308 B IM 308 C interface Programming device PG 730 PG 750 or PG 770 with CP 5410 S5DOS ST interface SINUMERIK or SIROTEC SINUMERIK 805SM SINUMERIK 840C SIROTEC ACR 20 with module IM ...

Страница 12: ...0C S5 95U DP or other PROFIBUS DP slaves Fig 1 2 Slave stations The diagram below gives an example of how to connect the master and slave stations to the SINEC L2 DP field bus SINUMERIK or SIROTEC ET 200 SINEC L2 DP field bus SIMATIC S5 155U CP 5410 B interface module Master IM 308 B interface module Slaves IM 328 N interface module SINEC L2 DP slave module ET 200 ET 200 ET 200 ET 200 Programming ...

Страница 13: ...r DC DC converter Slave S3 1 8 ON S2 1 8 ON Interface Interface X112 and LEDs have no function if they exist Station address for slave Units place 100 Tens place Hundreds place 101 100 199 0 99 FAULT red LED RUN green LED X21 3 5 3 5 Status display Slave X112 X111 X999 Switch position always down µP Fig 2 1 Module IM 328 N with the order number 6FC5 012 0CA03 0AA0 2 1 Hardware of the module 6FC5 0...

Страница 14: ...range of 4 8 16 or 32 input or output bytes Address range S2 1 in position S2 2 in position 4 bytes OFF OFF 8 bytes OFF ON 16 bytes ON OFF 32 bytes ON ON Note Address range of for example 4 bytes means that 4 input bytes and 4 output bytes are available with the same base address The following switches are used to set the module numbers base address S3 1 to S3 8 for an address range of 4 bytes S3 ...

Страница 15: ...ON OFF OFF 16 ON ON ON ON ON OFF ON ON 1020 OFF OFF OFF OFF OFF OFF OFF OFF Significance 29 512 28 256 27 128 26 64 25 32 24 16 23 8 22 4 Switch S2 1 OFF and S2 2 ON Base address S3 8 S3 7 S3 6 S3 5 S3 4 S3 3 S3 2 S3 1 0 ON ON ON ON ON ON ON x 8 ON ON ON ON ON ON OFF x 16 ON ON ON ON ON OFF ON x 24 ON ON ON ON ON OFF OFF x 32 ON ON ON ON OFF ON ON x 1016 OFF OFF OFF OFF OFF OFF OFF x Significance ...

Страница 16: ... x 32 ON ON ON ON OFF x x x 64 ON ON ON OFF ON x x x 96 ON ON ON OFF OFF x x x 992 OFF OFF OFF OFF OFF x x x Significance 29 512 28 256 27 128 26 64 25 32 x Switch position of no significance Note Base addresses are only possible for 4 byte 8 byte 16 byte or 32 byte steps depending on the address range For example an address range of 32 bytes permits only 0 32 64 96 etc as initial addresses Addres...

Страница 17: ...eaning Module is operated as a SINEC L2 DP slave standard DP see Section 3 2 Module is operated as a SINEC L2 DP slave up to V 3 x see Section 3 3 The module behaves like the 6FC5 012 0CA01 0AA0 module In assigning the slaves please note that the following I O ranges are availa ble on the SIROTEC ACR 20 SINUMERIK 805SM and SINUMERIK 840C controls SINUMERIK 805SM SW4 SIROTEC ACR 20 SW5 SINUMERIK 84...

Страница 18: ...SINUMERIK 805SM TW Interface Description Part 2 Connection Conditions Reference 4 SIROTEC ACR 20 Configuration Instructions Note The I O range must be addressed without gaps with SIROTEC ACR 20 Reference 5 SINUMERIK 840C Interface Description Part 2 Connection Conditions 2 1 Hardware of the module 6FC5 012 0CA03 0AA0 ...

Страница 19: ...green LED FAULT red LED Remark off on The module is being initialized this state lasts for a short period of time only on off Normal operating state slave in cyclic operation other states Fault for L2 DP DP standard see Section 3 2 5 for L2 DP to V3 x see Section 3 3 5 Via the interface X111 SUB D socket 9 way the slave is connected to the SINEC L2 DP field bus Note To connect up to the SINEC L2 D...

Страница 20: ...dth of front panel 1 1 3 SPS metal 1 SPS 15 24 mm Front connector 9 pin SUB D female connector bus interfaces Degree of protection IP 00 to DIN 40050 Permissible ambient temperature during operation 0 to 55 C Transport and storage temperature 40 to 70 C Humidity class F to DIN 40040 Shock resistance Class 12 to SN 29010 Mass 340 g Power supply 5 V 5 1 1 Amax Order No 2 1 Hardware of the module 6FC...

Страница 21: ...3 3 S3 5 S3 7 S5 1 S5 2 S5 3 S2 1 S2 2 S4 2 RESET F A U L T R U N Station address for slave Units place Tens place Hundreds place RESET Status display Slave RUN green LED Interface for slave 100 FAULT red LED X111 101 100 199 0 99 Bus connector Fig 2 2 Module IM 328 N with the order number 6FC5 012 0CA01 0AA0 Note This module has been superseded by the module 6FC5 012 0CA03 0AA0 2 2 Hardware of th...

Страница 22: ...o set the address range of 4 8 16 or 32 input or output bytes Address range S2 1 in position S2 2 in position 4 bytes open open 8 bytes closed open 16 bytes open closed 32 bytes closed closed Note Address range of for example 4 bytes means that 4 input bytes and 4 output bytes are available with the same base address The following switches are used to set the base address S3 1 to S3 8 for an addre...

Страница 23: ... OFF OFF 16 ON ON ON ON ON OFF ON ON 1020 OFF OFF OFF OFF OFF OFF OFF OFF Significance 29 512 28 256 27 128 26 64 25 32 24 16 23 8 22 4 Switch S2 1 OFF and S2 2 ON Base address S3 8 S3 7 S3 6 S3 5 S3 4 S3 3 S3 2 S3 1 0 ON ON ON ON ON ON ON x 8 ON ON ON ON ON ON OFF x 16 ON ON ON ON ON OFF ON x 24 ON ON ON ON ON OFF OFF x 32 ON ON ON ON OFF ON ON x 1016 OFF OFF OFF OFF OFF OFF OFF x Significance 29...

Страница 24: ...x x 32 ON ON ON ON OFF x x x 64 ON ON ON OFF ON x x x 96 ON ON ON OFF OFF x x x 992 OFF OFF OFF OFF OFF x x x Significance 29 512 28 256 27 128 26 64 25 32 x Switch position of no significance Note Base addresses are only possible for 4 byte 8 byte 16 byte or 32 byte steps depending on the address range For example an address range of 32 bytes permits only 0 32 64 96 etc as initial addresses Addre...

Страница 25: ...nflict with other I O modules results in wrong signal states and can cause an undefined behaviour of the control and the machine This switch must always be closed In assigning the slaves please note that different I O ranges are available on the SIROTEC ACR 20 SINUMERIK 805SM and SINUMERIK 840C con trollers see Section 2 1 1 Switch S4 2 I O ranges 2 2 Hardware of the module 6FC5 012 0CA01 0AA0 ...

Страница 26: ...l and the SINEC L2 DP field bus and initiates resynchronization Note Pressing the RESET button during cyclic operation of the module causes the control to stop and is therefore only permitted while the control is being started up The status display FAULT and RUN LED can indicate the following states of the SINEC L2 DP slave module RUN green FAULT red Meaning off on The module is being initialized ...

Страница 27: ... numbers are required Order number Designation 6ES5 762 2AA12 SINEC L2 bus connector degree of protection IP 20 without heavy duty thread socket 6ES5 762 2AA21 SINEC L2 bus connector degree of protection IP 20 with heavy duty thread socket For information about the bus cable and the bus connector see Reference 1 ET 200 Distributed I O System Manual 2 2 Hardware of the module 6FC5 012 0CA01 0AA0 ...

Страница 28: ...S metal 1 SPS 15 24 mm Base connector Plug connector to DIN 41612 96 pin Front connector 9 pin SUB D female connector bus interfaces Degree of protection IP 00 to DIN 40050 Permissible ambient temperature during operation 0 to 55 C Transport and storage temperature 40 to 70 C Humidity class F to DIN 40050 Shock resistance Class 12 to SN 29010 Mass 340 g Power supply 5 V 5 0 28 Atype J Order No 2 2...

Страница 29: ...ameterization software With the COM ET 200 parameterization software you can configure the ET 200 module system create the address list and analyze diagnostics data In this description it is assumed you have the parameterization software COM ET 200 Version 4 x 3 1 1 Installation Which PG PC can be operated on the SINEC L2 DP bus How is the CP 5410 S5DOS ST installed How is the COM ET 200 installed...

Страница 30: ...gured with the COM ET 200 configuration software The parameters for the slaves are then transferred during system start up After start up of the COM ET 200 package the required language can be selected Five languages are available After that COM ET 200 branches to the screen form FUNCTION SELECTION This screen form is the main screen form Here you are prompted to specify a program file in which to...

Страница 31: ...parameters and confi guration data for the IM 308 B Read in of a memory module into a program file Comparison of the creation data from program file and memory module Moreover you can transfer the configuration data created with COM ET 200 to a SINEC L2 DP master such as the IM 329 N This screen form gives you information about the current configuration status e g via the Set ET 200 system paramet...

Страница 32: ...ll selected modules It is also possible to force the outputs of the modules selected The DIAGNOSTICS OVERVIEW screen form lists the stations for which diagnostics data exist In the INDIVIDUAL DIAGNOSTICS screen form you can obtain the following information about the required station Station number Station type Station designation Station status Device and ID related diagnostics Note For operation ...

Страница 33: ...e in the ET 200 Distributed I O System For example the master IM 308 B or IM 329 N are used If the IM 308 B or IM 329 N module is the master PG PC with COM ET 200 V4 x Type file for IM 328 N see Section 3 1 1 Note About the system parameter BUS PROFILE Select the bus profile DP standard or DP FMS operation About the baud rate Baud rates up to 1500 kBaud are possible There is a separate configurati...

Страница 34: ...s of the first free byte as seen from the master is displayed for DI digital inputs DQ digital outputs The first address can also be entered and defined manually Configuration field Depending on the address range you can enter the following address identifiers in these input fields Address range Address ID 0 Address ID 1 4 bytes 51dec 8 bytes 55dec 16 bytes 63dec 32 bytes 2 16 bytes 63dec 63dec Th...

Страница 35: ...ddress and name 5 example for IM 328 N slave First available address DI 96 DQ 96 Address range 4 bytes Address identifier 51 see Section 3 2 1 Based on the above assumptions the CONFIGURING screen form must be parameterized as follows Program file selected C BEISP ET 200 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 51 F1 STATION DELETE STATION STATION NEW S...

Страница 36: ...uring Guide Reference 5 SINUMERIK 840C Interface Description Part 2 Connection Conditions Set the station address on the front panel in accordance with Section 2 1 2 Connect the module to the SINEC L2 DP field bus Switch on the control POWER ON and perform a RESTART of the PLC if required Note On the SINUMERIK 840C I O modules that have just been slotted in are not recognized until a cold RESTART ...

Страница 37: ...ample The configuration data are stored in the BEISP ET 200 program file A SIMATIC S5 115U is used as master PLC linear addressing I O area P 256 input and output bytes first available address is IB 96 QB 96 The station addresses 3 4 and 5 are to be set on the IM 328 N slave interface modules of the individual controls The address range for the stations 3 4 5 is to be 4 bytes 8 bytes 32 bytes and ...

Страница 38: ...INUMERIK 840C SIROTEC ACR 20 4 byte 8 byte 32 byte ON S2 1 S2 2 ON S2 1 S2 2 ON S2 1 S2 2 Setting of base address SINUMERIK 805SM SINUMERIK 840C SIROTEC ACR 20 ON S3 1 S3 8 IB 16 QB 16 ON S3 2 S3 8 ON S3 4 S3 8 IB 40 QB 40 IB 64 QB 64 I 513 Q 513 Enable slave ON S2 3 S2 4 Slave enabled Master disabled Station address for slave to be set on the front panel SINUMERIK 805SM SINUMERIK 840C SIROTEC ACR...

Страница 39: ...on DI DQ AI AQ 3 P 96 96 Module address I Q CONFIGURING IM 328 N slave interface module SINUMERIK 805SM IM 328 N slave DP Fig 3 4 Configuration of the slave in SINUMERIK 805SM Program file selected BEISP ET 200 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 55 Station No Area Station type Station name SIMATIC S5 COM ET 200 First available address Configuratio...

Страница 40: ...14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 63 Station No Area Station type Station name SIMATIC S5 COM ET 200 First available address Configuration DI DQ AI AQ 5 P 108 Module address I Q CONFIGURING IM 328 N slave interface module SIROTEC ACR 20 108 IM 328 N slave DP 63 Fig 3 6 Configuration of the slave in SIROTEC ACR 20 3 2 Description of the DP standard slaves ...

Страница 41: ... slaves SINUMERIK 805SM SINUMERIK 840C and SIROTEC ACR 20 IB 96 IB 99 QB 96 QB 99 QB 100 QB 107 IB 100 IB 107 IB 108 IB 139 QB 108 QB 139 SIMATIC S5 115U SINUMERIK 805SM SINUMERIK 840C SIROTEC ACR 20 IB 40 IB 47 QB 40 QB 47 IB 64 I 513 to I 520 IB 95 I 753 to I 760 QB 64 Q 513 to Q 520 QB 95 Q 753 to Q 760 IB 16 IB 19 QB 16 QB 19 Fig 3 7 Overview of data transfer Data transfer diagram 3 2 Descript...

Страница 42: ...switched off Configuration of the slave does not correspond to the configuration data of the master If threshold monitoring system parameter is activated a fault in data trans mission i e a bus fault is displayed by the STATUS DISPLAY SLAVE as follows RUN green LED FAULT red LED Meaning on on Fault during data transmission Reset of the inputs implemented by the slave in the slave station Cyclic at...

Страница 43: ...le error message displayed and can program the behaviour of the control in the case of this fault Fault on the module system error message System error messages are indicated by the flashing of the slave status indicator FAULT red LED Slave status indicator FAULT LED red Error message Comment 1 time on pause 1 time on Slave functionality dis abled Slave must be enabled via S2 3 see Section 2 2 1 2...

Страница 44: ...gnment and addressability are described in Reference 1 SIMATIC S5 Distributed I O System ET 200 because they can be used on all slave stations The diagnostics function must first be enabled in the ET 200 SYSTEM PA RAMETER screen form Y and a diagnostics address must be specified de fault diagnostics address 252 Diagnostics Y Diagnostics address 252 The diagnostics address is the address of the dia...

Страница 45: ...r 3 to 124 Code 0 to 7 T PW 252 After that the station diagnostics are transferred to the diagnostics word Eight words in each slave station are reserved for station status device oriented station diagnostics and ID oriented diagnostics module diagnostics Code Diagnostics address Diagnostics address 1 0 Station status 1 Station status 2 1 Station status 3 Master address 2 Manufacturer ID 3 Header ...

Страница 46: ...e until fault is remedied Bit is always 1 Response monitoring is activated Bit is always 0 Slave station is deactivated Slave station is in SYNC mode Slave station is in FREEZE mode Bit is always 0 Function is not supported Device oriented or ID oriented diagnostics exists Slave station has been para meterized by another master Slave station is not an IM 328 N parameter error The configuration dat...

Страница 47: ...th the device oriented diagnostics station diagnostics you can ascertain whether the PLC is in RUN or STOP state L KY n 3 Load diagnostics for Code 3 n station number T PW 252 and transfer the diagnostics words L KH 0200 Read and evaluate the diagnostics word L PW 252 Read the diagnostics word F If the diagnostics word is not equal to the comparison word BEB then SPB FBx evaluate fault in FBx Code...

Страница 48: ...nd of block otherwise evaluate error in FB x Diagnostics word from diagnostics OVERVIEW Diagnostics address Diagnostics address 1 Bit 7 6 5 4 3 2 1 0 Bit 7 6 5 4 3 2 1 0 Station Station n 16 7 n 16 6 n 16 5 n 16 4 n 16 3 n 16 2 n 16 1 n 16 n 16 15 n 16 14 n 16 13 n 16 12 n 16 11 n 16 10 n 16 9 n 16 8 has sent a diagnostics message has sent a diagnostics message You can use the following programmin...

Страница 49: ...ad diagnostics word Is bit 0 of the diagnostics address 1 byte set If so then no cyclic operation of the slave control evaluate in FBy correspondingly Reset of the inputs implemented by the slave in the master station A self defined sign of life bit can enable the user to detect a fault in cyclic operation of the slave station on the master side An output bit of the slave to be monitored is set on...

Страница 50: ...slave up to V3 x in the ET 200 Distributed I O System For example the master IM 308 B or IM 329 N can be used If the IM 308 B or IM 329 N module is the master then PG PC with COM ET 200 V4 x Note About the system parameter BUS PROFILE Select one of the bus profiles DP up to V 3x No DP standard slaves and no FMS stations e g IM 328 DP standard DP Siemens slaves standard slaves but not FMS stations ...

Страница 51: ...I digital inputs DQ digital outputs Configuration field Depending on the address range you can enter the following address identifiers in these input fields 8DE or 009 for 8 digital inputs 1 IB 8DA or 017 for 8 digital outputs 1 QB 011 for16 digital inputs 2 IB 019 for16 digital outputs 2 QB for address range 4 8 and 16 bytes for address range 32 bytes For an address range of 4 8 or 16 bytes first...

Страница 52: ... L2 DP module First free address DI 96 DQ 96 Address range 4 bytes address identifier for 8 digital inputs 8DI or 009 Address identifier for 8 digital outputs 8DQ or 017 Based on the above assumptions the CONFIGURING screen form must be parameterized as follows Program file selected C BEISP ET 200 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 8DE F1 STATION ...

Страница 53: ...d Address window 2 Install the module in the control Switch off the control Plug the module into a valid slot see 2 3 or 4 Set the station address on the front panel in accordance with Sections 2 1 2 and 2 2 2 Connect the module to the SINEC L2 DP field bus Switch on the control POWER ON and perform a RESTART of the PLC if required 3 Modify the configuration of the master IM 308 B Add the configur...

Страница 54: ...monitoring is activated the inputs of the station concerned are also not reset if a fault occurs but they remain unchanged The user can detect a fault in data transmission that is a fault of the cyclic operation between master and slave on the slave side by means of a user defined sign of life bit pre condition threshold monitoring activated An output bit of the slave to be monitored is set on the...

Страница 55: ...ve functionality must be enabled via S4 2 see Section 2 1 1 2 times on pause 2 times on Dual port RAM DPR is defective Replace module 4 times on pause 4 times on SPC defective Replace module 5 times on pause 5 times on Microcontroller is defective Replace module 6 times on pause 6 times on 7 times on pause 7 times on General hardware fault on the module Replace module Interface to the local bus of...

Страница 56: ...ault Diagnostics Parameter assignment and can be contacted Record all stations which have been parameterized and which can be con tacted Diagnostics Overview Record all stations from which diagnostics data exist Station diagnostics Evaluate station specific messages concerning the type of fault Module diagnostics or I O diagnostics For ET 200U Localize defective module For ET 200K Localize defecti...

Страница 57: ... O byte 252 The number of the station group n 0 1 2 7 is specified in the Diagnostics address 1 byte here I O byte 253 The diagnostics OVERVIEW comprises station n x 16 to station n x 16 15 for each station group The IM 308 B module writes the diagnostics message in the I O word 252 Read diagnostics OVERVIEW If no station has sent diagnostics message then end of block otherwise evaluate error in F...

Страница 58: ...agnostics OVERVIEW Call diagnostics OBERVIEW with station group 0 stations 0 to 15 and transfer into a flagword If station 5 has sent a diagnostics message then evaluate error in FB xx Note For detailed information on the diagnostics possibilities in the STEP 5 pro gram of the master control please refer to Reference 1 SIMATIC S5 Distributed I O System ET 200 If diagnostics shows that the station ...

Страница 59: ...tem is running PLC STOP is output in the slave station while the control is being powered up Reset of the inputs implemented by the slave module in the master station A self defined sign of life bit can enable the user to detect a fault in cyclic operation of the slave station on the master side An output bit of the slave to be monitored is set on the slave side and on the master side the signal s...

Страница 60: ...rmation required for start up and service Block 3 Searching aids So that you can find the information you need this document not only contains a table of contents a list of figures and a list of tables but in the appendix you will also find 1 A list of abbreviations 2 A list of references 3 An index S ii Note Text marked in this way is important information to which the reader must pay special att...

Страница 61: ...8 N and IM 329 N modules The modules new old and master and slave have different applications as follows Table 1 1 Different applications between IM 328 N and IM329 N Use as Module Slave for SINEC L2 DP to V3 x Slave for SINEC L2 DP PROFIBUS DP acc to DIN E 19245 part 3 Master For information on the IM 329 N see Reference 7 Description Link with the SINEC L DP with IM 329 N module Tradenames SIMAT...

Страница 62: ...Order No 6FC5 012 0CA03 0AA0 S 2 2 Block 1 Selecting the control system S2 5 S2 6 S2 7 and S2 8 The module can be used in the control systems listed The control type must be set with switches S2 5 S2 6 S2 7 and S2 8 as follows Block 2 Note The IM 328 N module can only be used for SINUMERIK 805SM in the cen tral controller Block 3 Note Address space of for example 4 bytes means that 4 input bytes a...

Страница 63: ...e 3 1 Setting for the type of communication Meaning Module is operated as a SINEC L2 DP slave standard DP see Section 3 2 Module is operated as a SINEC L2 DP slave up to V 3 x see Section 3 3 The module behaves like the module I O ranges In assigning the slaves please note that the following I O ranges are available on the SIROTEC ACR 20 SINUMERIK 805SM and SINUMERIK 840C con trols Inputs EB IB bi...

Страница 64: ...onnector degree of protection IP 20 with heavy duty thread socket For information about the bus cable and the bus connector see Reference 1 ET 200 Distributed I O System Manual S 2 9 2 2 Hardware of the module Bildinschriften wie alte Vorlage S 2 1 mit folgenden zusätzlichen Inschrif ten für Slave for slave Unterschrift Fig 2 2 IM 328 N with the order number Note This module has been superseded by...

Страница 65: ...states and can cause an undefined behaviour of the control and the machine Switch S4 2 This switch must always be closed I O ranges In assigning the slaves please note that different I O ranges are available on the SIROTEC ACR 20 SINUMERIK 805SM and SINUMERIK 840C control lers see Section 2 1 1 S 2 14 2 2 2 Elements on the front plate ganze S bis auf letzter Absatz wie alte Vorlage S 2 5 aber mit ...

Страница 66: ...e during operation 0 to 55 C Transport and storage temperature 40 to 70 C Humidity class F to DIN 40050 Shock resistance Class 12 to SN 29010 Mass 340 g Power supply 5 V 5 0 28 Atype S 3 1 Use Table 4 1 Applications of the IM 328 N Use as Module Slave for SINEC L2 DP up to V3 x Slave for SINEC L2 DP PROFIBUS DP acc to DIN E 19245 part 3 3 1 COM ET 200 parameterization software With the COM ET 200 ...

Страница 67: ...terization software Principle With the ET 200 Distributed I O System the master is always configured with the COM ET 200 configuration software The parameters for the slaves are then transferred during system start up Start up and language selection After start up of the COM ET 200 package the required language can be se lected Five languages are available After that COM ET 200 branches to the scr...

Страница 68: ... ET 200 to a SINEC L2 DP master such as the IM 329 N Block 3 Address assignment and system documentation This screen gives you information about the current configuration status e g via the n Set ET 200 system parameters n Assigned station numbers n Station oriented address assignment for one station you ob tain the information Query In which slot is the module inserted What addresses to the input...

Страница 69: ...Section 2 1 1 3 2 1 Notes on parameterization of the slaves Here are some notes that must be observed when the IM 328 N is used as a standard slave in the ET 200 Distributed I O System For example the master IM 308 B or IM 329 N are used Prerequisites for slave parameterization If the IM 308 B or IM 329 N module is the master PG PC with COM ET 200 V4 x Type file for IM 328 N see Section 3 1 1 ET 2...

Страница 70: ... the IMI 308 B Write to the memory module For the IM 329 N master perform DOWNLOAD Reference 7 SIROTEC ACR20 SINUMERIK SM 840C Link to SINEC L2 DP with module IM 329 N S 3 14 Normal operating state Tabelle Normal operation is displayed via the status display as follows grün green rote red ein on aus off Bedeutung Meaning Normal operation slave is in cyclic mode Tabelle weiter unten wie oben mit Fa...

Страница 71: ...iew and Parameter assignment and addressability are described in Reference 1 SIMATIC S5 Distributed I O System ET 200 because they can be used on all slave stations Enabling diagnostics The diagnostics function must first be enabled in the ET 200 SYSTEM PARA METER screen form Y and a diagnostics address must be specified default diagnostics address 252 Diagnostics Y Diagnostics address 252 The dia...

Страница 72: ...ter address Manufacturer ID Header Device oriented diagnostics station diagnostics Header ID oriented diagnostics module diagnostics Unused Unused Unused Unused Unused Unused S 3 18 Requesting station status and evaluating Code 0 and Code 1 The bytes station status 1 to 3 provide information about the station The byte master address contains the address of the master station that the slave station...

Страница 73: ...tation is in SYNC mode Bit is always 0 Slave station is deactivated Fig 3 9 Structure of the diagnostics word after request with Code 0 Bild Code 1 Station 3 and Master address Without meaning Address of the master of that has parameterized the slave station Fig 3 10 Structure of the diagnostics word after request with Code 1 S 3 19 Requesting manufacturer ID Code 2 The byte manufacturer ID descri...

Страница 74: ... used or The module with the order number is used and jumper X999 is set for opera tion as a SINEC L2 DP up to V3 x see Section 2 1 1 3 3 1 Notes on parameterization of the slaves Here are some notes on how to use the IM 328 N as an L2 DP slave up to V3 x in the ET 200 Distributed I O System For example the master IM 308 B or IM 329 N can be used Preconditions for slave parameterization If the IM ...

Страница 75: ...the following address identi fiers in these input fields 8DI or 009 for 8 digital inputs 1 IB for address range 4 8 and 16 bytes 8DA or 017 for 8 digital outputs 1QB 011 for 16 digital inputs 1 IB for address range 32 bytes 019 for 16 digital outputs 2 QB For an address range of 4 8 or 16 bytes first the address identifier 8DI and then the address identifier 8DQ must be entered 4 times 8 times or ...

Страница 76: ...GURING screen form must be parameterized as follows Maske Program file selected C BEISP CONFIGURING Station number 5 Area P Station type Station name SINEC L2 DP module First available address DE 96 DA 96 AE AA Configuration Module address I Q etc STATION LÖSCHEN DELETE STATION NEUE STATION NEW STATION ADRESS BELEGUNG ADDRESS ASSIGNMENT UEBERNAHME ENTER Fig 3 13 CONFIGURING screen form S 3 25 3 3 ...

Страница 77: ... 3 26 3 3 4 Fault during data transmission Rest von alter S 6 1 übernehmen ohne Änderungen die für neue S 3 14 3 15 gemacht wurden aber gelb markierten Änderungen mit schwarzer Schrift bitte auch übernehmen S 3 27 Messages via status display Rest der S von alter S 6 2 übernehmen ohne Änderungen die für neue S 3 15 gemacht wurden Folgende Änderungen auch noch berücksichtigen Tabellenüberschrift Tab...

Страница 78: ...TOP in the slave station If diagnostics shows that the station to be checked has an error and can be ad dressed the MODULE DIAGNOSTICS can be used to detect cyclic operation of the slave control as follows S 3 31 Call module diagnostics from the SINEC L2 DP slave module Enter station number here 5 can be between 2 and 124 in the diagnostics address byte The diagnostics address 1 byte always has th...

Страница 79: ...he DP master via SINEC L2 DP bus DP Distributed I Os DP master e g IM 308 B IM 329 N DP standard Procedure acc to PROFIBUS DP DIN E 19245 Part3 DPR DUAL PORT RAM memory that can be accessed both ways read and write access DW Data word IB Input byte ET 200 Electronic Terminator 200 distributed I O system 200 S A 2 ET 200B Distributed I O device to degree of protection IP 20 small and compact there ...

Страница 80: ...ss Field BUS German process and fieldbus standard defined in the PROFIBUS standard DIN 19245 This standard defines functional electrical and mechanical characteristics for bit serial fieldbus systems S A 3 PROFIBUS DP Standard proposal PROFIBUS DP DIN E 19245 Part 3 on which the distri buted I O system ET 200 is based PW I O word TO Timeout RAM Random Access Memory SPS Standard plug in station 1 S...

Страница 81: ...Order No 6ES5 998 4ET21 Distributed I O Device ET 200C Manual Order No 6ES5 998 3EC21 Programmable Controller S5 95U SINEC L2 DP Interface Manual Order No 6ES5 998 8MD21 unten SIROTEC ACR 20 SINUMERIK 805SM 840C Link to SINEC L2 DP with Module IM 328 N Description Order No 6ZB5 430 0BH02 0AA0 SIROTEC ACR 20 SINUMERIK 805SM 840C Link to SINEC L2 DP with Module IM 329 N Description Order No 6ZB5 430...

Страница 82: ...UAL PORT RAM memory that can be accessed both ways read and write access Digital outputs Data word Electronic Terminator 200 distributed I O system 200 Distributed I O device to degree of protection IP 20 small and compact therefore suitable if only a few inputs outputs are required or if available mounting depth is small Distributed I O device compact design to degree of protection IP 65 for use ...

Страница 83: ...us SINEC L2 DP Light emitting diode Organization block Output byte Programming unit Process output image Process input image Programmable Logic Controller PROcess Field BUS German process and field bus standard defined in the PROFIBUS standard DIN 19245 This standard defines functional electrical and mechanical characteristics for bit serial field bus systems Standard proposal PROFIBUS DP DIN E 19...

Страница 84: ... system and field devices on the cell and field level Bus system SINEC L2 with DP protocol stands for distributed peripherals Softkey Serial Periphery Controller Standard plug in station 1 SPS 15 24 mm Static RAM buffered Each ET 200 bus node is assigned a unique station number Software Version x Timeout J SINEC L2 SINEC L2 DP SK SPC SPS SRAM Station number SWx TO ...

Страница 85: ...U Programmable Controller SINEC L2 DP Interface Manual Order No 6ES5 998 8MD21 SINUMERIK 805SM TW Interface Description Part 2 Connection Conditions Order No 6ZB5 440 0MD01 0AAx SIROTEC ACR 20 Planning Guide Order No 6ZB5 430 0BL01 0AAx SINUMERIK 840C Interface Description Part 2 Connection Conditions Order No 6FC5 197 xAA10 0BP0 SIROTEC ACR 20 SINUMERIK 805SM 840C Link to SINEC L2 DP with Module ...

Страница 86: ...nt plate Module 6FC5 012 0CA01 0AA0 2 14 Module 6FC5 012 0CA03 0AA0 2 7 H Hardware Module 6FC5 012 0CA01 0AA0 2 9 Module 6FC5 012 0CA03 0AA0 2 1 J Jumper settings Module 6FC5 012 0CA01 0AA0 2 10 Module 6FC5 012 0CA03 0AA0 2 2 M Master stations 1 1 P Parameterization DP slave up to V3 x 3 22 DP standard slave 3 5 R References B 1 S SINEC L2 DP field bus 1 1 Slave stations 1 2 Startup DP slave up to...

Отзывы: