Description
3-3
Siemens AG 1996 All Rights Reserved 6ZB5 430–0BH02–1AA0
SINUMERIK 805SM / 840C (BS)
After input of the new program file and confirmation, e.g., of softkey F1 in
the function selection screen form, you are prompted to select the master
type.
Please select:
<
F1
>
: DP master is an IM 308–B
<
F3
>
: General DP master
Fig. 3-1
Selecting the master type
After you have selected the master type, the following functions are
available:
Here you enter all parameters required for the correct operation of system
ET 200, such as baud rate, type of addressing, CPU type, and behaviour in
the case of a station failure.
Enter the CONFIGURING data of each individual ET 200 slave station in the
configuring screen form.
The TRANSFER FUNCTIONS screen form permits the following for a
memory module:
Programming of a memory module with system parameters and confi-
guration data for the IM 308–B.
Read–in of a memory module into a program file.
Comparison of the creation data from program file and memory module.
Moreover, you can transfer the configuration data created with COM ET 200
to a SINEC L2–DP master (such as the IM 329–N).
This screen form gives you information about the current configuration
status, e.g. via the
Set ET 200 system parameters
Assigned station numbers
Station–oriented address assignment for one station you obtain the
information:
Query:
In which slot is the module inserted?
What addresses do the inputs and outputs have?
Address assignment range–oriented for one address range each
(e.g. the P range):
Which inputs and outputs are assigned to which stations?
To which slot and to which module type is each input and output
assigned?
You can also print out the current configuration status.
Selecting the
master type
ET 200
system parameters
Configuring
TRANSFER
functions
Address assign-
ment and system
documentation
3.1 Parameterization software COM ET 200