Description
2-14
6ZB5 430–0BH02–1AA0
Siemens AG 1996 All Rights Reserved
SINUMERIK 805SM / 840C (BS)
2.2.2
Elements on the front plate
The rotary switch is used to set the units place (first switch from top) and the
tens place (second switch from top) of the station address.
The hundreds place of the station address depends on the setting of the toggle
switch (upper position = 1 x 100, lower position = 0 x 100). Valid station ad-
dresses are between 3 and 124.
Note
The software limits the station address to the range from 3 to 124.
A change in station address does not become active until after a restart of
the control.
Pressing the RESET button on the module interrupts the interface to the
control and the SINEC L2-DP field bus and initiates resynchronization.
Note
Pressing the RESET button during cyclic operation of the module causes the
control to stop and is therefore only permitted while the control is being
started up.
The status display (FAULT and RUN LED) can indicate the following states
of the SINEC L2-DP slave module.
RUN (green)
FAULT
(red)
Meaning
off
on
The module is being initialized
(this state lasts for a short period of time only)
on
off
Normal operating state, slave in cyclic operation
on
on
Fault during data transmission, module not in cyclic
operation (see also Section 3.3.4)
on
flashing
Fault on the module, system error message (see also
Section 3.3.5)
Via the interface X111 (SUB–D, socket, 9–way), the slave is connected to the
SINEC L2–DP field bus.
Station address
RESET button
Status display of
the slave (LEDs)
Interface for slave
2.2 Hardware of the module 6FC5 012–0CA01–0AA0