Device description
5
5.1
Functions
What is possible?
The IE switches of the SCALANCE X-200RNA product line allow the cost-effective setup of IE
structures with PRP or HSR functionality. You can also implement the transition between a PRP
and an HSR network with the SCALANCE X-200RNA.
Product properties
The SCALANCE X204RNA and the SCALANCE X204RNA EEC devices have the same functionality
and differ only in the environmental conditions, the input voltage ranges and the option of using
SFP modules with the SCALANCE X204RNA EEC.
Properties
SCALANCE X204RNA
SCALANCE X204RNA EEC
SIMATIC environment
●
●
Operating temperature
-40 to +60 °C
-40 to +70 °C (up to 85 °C max.)
16h)
Diagnostics LED
●
●
24 V DC
●
-
24 ... 250 V DC / 100 ... 240 V AC
-
●
Housing
Plastic
Metal
Coated printed circuit boards
-
● (as of hardware version 3)
2 x 24 V DC
●
-
100 Base-T, full duplex
●
●
100 Base-T, half duplex
-
-
10 Base-T
-
-
SFP interface for SFP modules for
HSR ports
-
●
100 Base-FX for HSR ports
-
● (using optional SFP modules)
Signaling c on-site opera‐
tion (SELECT/SET button)
●
●
Diagnostics:
via Web Based Management (WBM)
via e-mail notification (SMTP)
via SNMP V1,V2,V3 incl. Traps V2
using SYSLOG server notification
●
●
●
●
●
●
●
●
C-PLUG
●
●
IRT capability
-
-
SNTP
●
●
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
31
Содержание 6GK5204-0BA00-2KB2
Страница 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 14: ...Safety notices SCALANCE X 200RNA 14 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 18: ...Security recommendations SCALANCE X 200RNA 18 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 80: ...Connecting up 7 5 Grounding SCALANCE X 200RNA 80 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 82: ...Maintenance and cleaning SCALANCE X 200RNA 82 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 152: ...Technical specifications SCALANCE X 200RNA 152 Operating Instructions 04 2022 C79000 G8976 C342 07 ...