Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
53
5.
Fit the connector
–
Fit the lower cable clamp into the grooves of the connector casing.
–
Fit the cable into the connector casing so that the braided shield with the copper band
lies in the cable clamp
–
Fit the upper cable clamp into the grooves of the connector casing and screw it tight
–
Match the wire pairs to the screw terminals
You will find the assignment required for a particular cable type in the section
–
Secure the conductors in the screw terminals
–
Screw the cover on to the connector casing
5 12 3 10
%UDLGHGVKLHOG
ZUDSSHGZLWK
FRSSHUEDQG
6KLHOGIRLO
Figure 2-4
15-pin D-sub plug fitted to the standard cable