Instructions for fitting connectors, attachments and devices
2.2 Industrial Ethernet FastConnect Stripping Tool
Passive network components
10
System Manual, 02/2013, C79000-G8976-C282-01
6.
Clamp the stripping tool as far as it
will go.
7.
To strip the insulation, turn the tool
in the direction of the arrow
–
approx. 4 times for PVC
insulation
–
approx. 8 times for PUR
insulation
8.
Keeping the it closed, pull the
stripping tool with jacket and
remnants of the shield off the end of
the cable.
If the cutting result is poor, change
the knife cassette.
9.
After releasing the tool, remove the
remnants of the cable from the tool.
10.
If the white filler is not removed with
the insulation, remove it with your
hand.
11.
The protective foil is easier to
remove if you score it between the
wires with a screwdriver.
12.
Pull the protective foil off the wires. 13.
When assembling the cable, follow
the installation instructions supplied
with your connector or outlet.
14.
Replace the knife cassette after
approx:
–
1500 operations on cables with
PVC outer jackets
–
150 operations on cables with
PUR outer jackets