Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
25
5.
Use the stripping tool 6GK1 901-
1GA00 with the green knife
cassette 6GK1 901-1GB01.
6.
Measure the cable length against
the measuring template. The
correct length is indicated by the
marker with the number 6GK1901-
0DB....
Note: If the required marks are not
available on the stripping tool, make a
mark manually 32 mm from the left-
hand edge.
7.
Insert the cable. Your index finger
acts as the limit stop.
8.
Clamp the stripping tool as far as it
will go.
9.
Turn the stripping tool as follows:
–
4 times for PVC cables,
–
8 times for PUR cables
in the direction of the arrow and
remove remnants of the jacket
and if necessary nip off the
dummy elements.
10.
Open the flap (e) and push the
wires according to the colored
marking* as far into the holder as
they will go.
11.
Press down the holder flap (e) until
it is fully closed. Make sure that the
jacket shield fully covers the shield
contact surface.
*To create a crossover cable, connect
white with yellow and blue with orange
at one end of the cable.
12.
Push the connector housing (b) up
to the front part of the connector (a).
13.
Screw the connector housing and
the front of the connector together
until the catch (c) locks in position.
14.
Screw the pressure nut (d) and the
connector housing together with a
torque of 1.3 Nm +0.2.
Note
Replace the knife cassette if the cut
is not clean or after stripping
approximately
–
1500 operations on cables with
PVC outer jackets
–
150 operations on cables with
PUR outer jackets
The piercing contacts of the IE FC
M12 Plug PRO can be released and
re-used up to 10 times. Cable ends
that have already been pierced
must not be used again but must be
cut off.
Screw the IE FC M12 plug PRO to
devices with a torque of 0.6 Nm +/-
0.1.