A5E00264365A
Siemens AG Operating Instructions 2.02 1PL622
47
Operation
5
5.1
Operation
Safety notes
WARNING
Please follow all instructions contained in the "Safety information and application
information (Page 7)" chapter of these operating instructions precisely and ensure that only
persons who have the necessary specialist know-how are entrusted to carry out work on
power installations.
WARNING
Rotating components
Covers prevent contact with live or rotating parts, or are used for proper air routing and thus
effective cooling of the motor.
Removing the covers during operation can result in death, serious injury, and property
damage.
Never open covers during operation.
CAUTION
Speed monitoring
The motor is designed for a certain speed range.
If a motor is operated at impermissible speeds damage to the winding, bearings, or
complete destruction of the motor can be the result.
Ensure that the speeds specified on the rating plate are not exceeded by appropriately
configuring controller and speed monitoring components.
Switching on
●
See the operating instructions of the frequency converter for switching on.
●
After starting the motor, observe it for a while to see if it is running smoothly and check
the monitoring devices.
Содержание 1PL622
Страница 1: ...Operating Instructions Edition 03 2008 Three phase induction motor AC COMPACT DRIVES Type 1PL622 ...
Страница 2: ...26 03 2008 10 58 ...
Страница 8: ......
Страница 16: ......
Страница 24: ......
Страница 44: ......
Страница 52: ......
Страница 70: ......
Страница 76: ......
Страница 80: ......
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ...AB U151 Herstellererklärung AB U161 Konformitätserklärung ...
Страница 86: ......