ENGLISH
22
610.43 600.21
Siemens AG
5.2
Electrical connections
Circuit diagram
Fig. 6 Circuit diagram
Power plug
- Use connector size 1.5 or 3
- Make the plug assignment as shown in Fig. 7, connect the PE conductor.
- Connect the optional brake via the power plug as shown in Fig. 7.
Fig. 7 Power plug (view of plug pins)
NOTICE
Improper change of the cable output direction leads to damage to the
connecting cables.
The cable outlet direction must not be changed, and doing so will lead to the
loss of claims under warranty.
L1
L2
L3
3
3
U
V
W
U2
V2
W2
Supply
Motor
Encoder
BR
(+)
BR2
(-)
U V W
3
M
Motor
Brake
BR
GNYE
BR2
V
W
U
Connector size 1,5
Connector size 3
V
W
U
BR
BR2
GNYE
Содержание 1FT6 13