ENGLISH
14
610.43 600.21
Siemens AG
Cooling Self-cooling
(EN 60034-6)
Forced ventilation
Water-cooling
A-grade measuring-surface sound-pressure level
(EN 60034-9) for speed range up to 3,000 rpm; Tol3 dB (A)
Self and water cooling
approx. 70 dB(A)
Forced ventilation
approx. 74 dB(A)
Thermal motor protection
KTY84 temperature sensor in the
(EN 60034-11)
stator winding
Shaft end
cylindrical; without keyway
(DIN 748-3; IEC 60072-1)
and without key
True running, coaxiality, axial run-out deviation Tolerance N
(DIN 42955; IEC 60072-1)
Vibration severity
grade N
(EN 60034-14)
Bearing
Rolling contact bearing with permanent
grease lubrication (lifetime lubrication)
Fixed bearing on the drive end
Service life of bearing
20000 h (recommended value)
Winding insulation
Insulating material class F
(EN 60034-1)
Ambient temperatures
-15 °C to +40 °C (5 °F to 104 °F)
if water-cooled
+5 °C to +40 °C (41 °F to 104 °F)
Installation altitude
≤
1000 m [3280 ft.] above mean sea level
(EN 60034-1)
otherwise the rated data are reduced
2000 m [6562ft] conversion factor 0,94
2500 m [8202ft] conversion factor 0,9
Magnetic material
Rare-earth material
Electrical Connection
Power
Terminal box
Connector
Encoder signal:
Connector
Encoder system
fitted encoder
- speed recording
- recording the rotor position
- indirect positional recording
Additional technical parameters, dimensional sheets according to project planning guide
6SN1197-0AA20.
Options/expansions
Degree of protection
IP 65, IP67, IP68
(EN 60034-5)
(forced ventilation module IP54)
Fitted/mounted
- closed current holding brake;
supply voltage 24 V DC ±10% /
230 V AC ±10%
- Planetary gearing
Содержание 1FT6 13