8.4 Timer function
The
Timer
button is used to activate/deactivate the timer function. When the timer is activated, the
timer starts the unit for a preset run time (in hours). This is preset at the factory to 8 hours.
The blower automatically switches off after the running time has elapsed.
24 hours after the timer has been activated, the unit restarts automatically with the settings that were
last selected. This procedure is repeated cyclically every 24 hours.
The function ends when the timer is switched off.
Note:
After a power failure, the timer must be reactivated.
Setting the timer
The timer running time may be set to a value between 1 and 18 hours and can be changed at any
time
1. Press the
Timer
button 1x (pressing the
button again ends the timer function).
2. Adjustment of the running time:
- To shorten the running time, press the
–
button immediately.
- To extend the running time, press the
+
button immediately.
Note:
The display lights up briefly, the clock
symbol flashes, and the set blower level plus
the running time in hours are displayed
Note:
Approx. 5 seconds after the running
time has been set, the display changes to show
the remaining run time.
• Remaining running time: 5:59 hours (set
running time: 6:00 hours)