64
TCIP 603-03
Door controller IP TCIP 603-… as
a control unit for management of
access entitlement in private homes
and commercial properties.
It is operated directly via a PC
network (Ethernet standard
10/100 Mbit). Operation takes place
using Microsoft Internet Explorer,
current Version.
• Actuation possible via code lock
module COM 611-…, electronic
key reading module ELM 611-…
or fingerprint module FPM 611-…
To increase security, two different
access modules – e.g. COM/
FPM 611-… – can be used in com-
bination.
• Password protected
• Central management in the net
-
work via any optional PC (Internet
Explorer current version)
• Logging of access and system data
• Attendance/absentee list as log
(when using separate entrance and
exit readers, i.e. 2 readers per door)
• 5 entrances (e.g. door contacts)
• 4 exits (e.g. door release)
• with FSM 740-… and SCE 640-…
extension possible by further inputs
and outputs
• Connection to Ethernet via RJ45
interface
• LEDs for status display of entrances
• 20 different time models possible
• Max. 40 access groups
• Management of up to 8 doors
• Max. 500 users with 4 character-
istics per user such as fingerprint,
card or code
• Max. 100 fingerprints can be
scanned in
TCIP SRV 603-0
The Door controller IP server
TCIP SRV 603-… is used to net-
work several door controllers
IP TCIP 603-… and to extend the
maximum number of users which
can be managed to over 500.
Frequent settings and changes under
the headings Time profiles, Public holi-
days/vacation, Access groups and users
are centrally managed and stored for
several TCIP 603-… units.
• Password protected
• Central management in the network
via any optional PC (Internet Explorer
current version)
• Logging of access and system data
• Attendance/absentee list as log
(when using separate entrance and exit
readers, i.e. 2 readers per door)
• Over 500 users, depending on the
capacity of the network
• Max. 100 fingerprints can be scanned
in
• Local configuration of menu points
Inputs, Outputs, Readers, Network,
System time/Time change and Doors
• Automatic time adjustment (when
accessing NTP time server)
Operating voltage: 90–264 V AC,
47–63 Hz
Typical current consumption: max. 45 W
Horizontal pitch (HP): 3 x 12
Ambient temperature:
+10 °C to +50 °C
Dimensions (mm) W x H x D:
328 x 88.8 x 201
• Variable public holiday and vaca
-
tion profiles
• Automatic time changeover (sum
-
mertime/normal time)
Operating voltage: 20–30 V DC
Operating current: max. 700 mA
Contact type: Contact 15 V AC,
30 V DC, 2 A
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Dimensions (mm) W x H x D:
131 x 111 x 52
7 Access control through the Vario bus
Distribution components – Server/controller
TCIP 603