69
Device type
Switching inputs
E1
E2
Indoor stations
AHF/AHFV/AHT/AHTV/AVP
Potential-free
contact
min. 20 V DC,
10 mA
Terminals (3, 6)
Storey call button
(ERT)
-
-
-
Indoor station upgrade AZIO
-
Potential-free
contact
min. 20 V DC,
10 mA
Terminals (1, 2)
-
Door controller
ATLC
Potential-free
contact
min. 20 V DC,
10 mA
Terminals (15, 16)
Galvanically iso
-
lated
max. 4-30 V DC,
10 mA
Terminals (17, 18)
-
-
Door controller extension
ATLCE
Potential-free
contact
min. 20 V DC,
10 mA
Terminals (15, 16)
Galvanically iso
-
lated
max. 4-30 V DC,
10 mA
Terminals (17, 18)
Potential-free
contact
min. 20 V DC,
10 mA
Terminals (25, 26)
Galvanically iso
-
lated
max. 4-30 V DC,
10 mA
Terminals (27, 28)
The Siedle Access device log is avail
-
able for commissioning support and
documenting the switching outputs
and inputs used.
The Siedle Access device log can be
found in the Siedle download area/
as a supplement for each of the
network-capable Access compo-
nents at www.siedle.com