Notes on the circuit diagram
a)
If door releases or gate control
systems are fitted and their con-
nected values do not correspond to
12 V AC/DC and min. 20 Ohm, then
either switching output 2 (ATLC ter-
minals 13/14 (output)) or switching
output 3 (ANG terminals 11/12/14
(output)) can be used as a potential-
free door release contact.
To use switching output 2 or 3 as a
potential-free door release contact,
you must configure the corre-
sponding ATLC switching output in
the Access administration interface.
•
The use of the potential-free
switching outputs is described in
separate diagrams.
(For detailed information, see
page
l)
The internal wiring of the Classic
door station is completed on site by
the customer.
• The connection of the call button
modules is described in a separate
diagram. (For detailed information,
see page
q)
Where there are more than 20
backlit call buttons, an additional
12 V AC supply, for instance
TR 603-…, must be installed due
to the current consumption. To use
the additional supply, the jumpers
between the CATLE and the call but
-
tons from b1/c1 to b/c are removed
and the b/c terminals are directly
connected to the additional supply.
The jumpers from the ACM camera
module to CATLE between the ter
-
minals V3/V4 and the terminals b1/
c1 remain as they are.
•
Supply limits ATLC/NG 670-…
(For detailed information, see
page
• The use of an additional power
supply is described in a separate
diagram.
(For detailed information, see
page
y)
The circuit diagram shows an
exemplary connection of call buttons
with the BRMA.
• (For detailed information, see