DIP switch
Single-axis drive amplifier
Double-axis drive amplifier: 16 Byte In
12
- - -
- - -
13
Drive amplifier 7
- - -
14
- - -
- - -
15
- - -
- - -
16
- - -
- - -
The following example shows the settings of the DIP switches for 4 double-axis drive
amplifiers and 4 single-axis drive amplifiers with 14 bytes input data:
DIP switch
Single-axis drive amplifier
Double-axis drive amplifier: 14 Byte In
1
- - -
Drive amplifier 1, drive A
2
- - -
Drive amplifier 1, drive B
3
- - -
Drive amplifier 2, drive A
4
- - -
Drive amplifier 2, drive B
5
- - -
Drive amplifier 3, drive A
6
- - -
Drive amplifier 3, drive B
7
- - -
Drive amplifier 4, drive A
8
- - -
Drive amplifier 4, drive B
9
Drive amplifier 4
- - -
10
- - -
- - -
11
Drive amplifier 5
- - -
12
- - -
- - -
13
Drive amplifier 6
- - -
14
- - -
- - -
15
Drive amplifier 7
- - -
16
- - -
- - -
The designations in and out refer to the viewpoint of the gateway. That
means, depending on the protocol the gateway receives 14 or 16 bytes from
the PLC (in) and sends always 16 bytes to the PLC (out).
6.2
Connector Pin Assignment
6.2.1
X2 – PROFIBUS slave Connection
9-pole female submin D connector
Pin
I/O
Name
Meaning
1
Shield
Cable shield
2
n.c.
Ground
3
I/O
RxD / TxD-P (B)
Transmit/receive data (PROFIBUS)
4
O
RTS
Request to send
5
I/O
GND
Reference ground for bus termination
6
VCC5
5 V supply voltage for bus termination
7
n.c.
8
I/O
RxD / TxD-N (A)
Receive / transmit data (slave)
Connectors, Switches and Displays
W
32
Gateway 0362151A - PROFIBUS to SERVOLINK 4 Safety
6
Содержание 036215
Страница 1: ...Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety P TD 0000331 12 2019 04 09 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety ...
Страница 16: ...Safety Instructions W 16 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 2 ...
Страница 18: ...Unit Assembly Complying EMC W 18 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 3 ...
Страница 26: ...Gateway 0362151A W 26 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 4 ...
Страница 28: ...Mounting and Demounting W 28 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 5 ...