The following climatic conditions apply to the storage. If required, appropriate meas‐
ures must be taken to ensure these climatic conditions (installation of heating/air condi‐
tioning systems etc.):
▶
The storage area must be clean (dust-free, if possible), dry and well-ventilated.
▶
No storage in the open.
▶
The storage temperature must be in the range of −25 °C to +55 °C (−13 °F to
+131 °F). Shortly it may be +70 °C (+158 °F).
▶
The relative humidity on the storage premises must be in the range of 5 % to 75 %
(no bedewing).
▶
Sudden changes of the temperature or the humidity should be prevented.
▶
Avoid stacking of the devices during transport and storage.
The maximum storage period is 2 years. Electrolytic capacitors produce high leakage
currents when a voltage is applied after a long storage period without applied voltage
and must be reformed. For this, the operating voltage is applied via a 1 kΩ series
resistor for one hour. Please contact the SIEB & MEYER service department for
details.
2.6
Installation
NOTICE
Damage of electrostatically sensitive components due to improper handling
Never touch electronic components.
Consider specific mounting instructions for your device.
Operating conditions:
The following requirements are to be considered for the installation and the operation
of the device. Noncompliance with theses requirements is regarded as abnormal oper‐
ating condition:
▶
The device is conceived according to DIN EN 61800-1 / DIN EN 50178 for the dirt
level 2.
▶
Devices with air cooling only can be loaded to their maximum up to a height of
1000 m above MSL (3281 ft above MSL). For an operation in areas higher than
1000 m (3281 ft) above MSL the capacity must be reduced by 1.5 % per 100 m
(328 ft).
▶
The device must be protected against harmful gas, oil vapor and salty air at the
place of installation.
▶
The ambient air must not contain aggressive, grinding, electrically conductive or
flammable substances as well as any amount of dust.
▶
The maximum relative humidity during operation is 85% (no condensation).
▶
The admissible ambient temperature during operation is +5 °C to +40 °C (+41 °F
to +104 °F). Extreme and sudden changes of the temperature should be
prevented.
─
Devices that are operated at ambient temperatures b40 °C (+104 °F)
and +60 °C (+140 °F) will probably have a reduced service life due to
increased wear of the components.
─
Devices with polyester film at the front panel: The polyester films must not be
exposed to direct sunlight for extended periods of time. In conditions of high
humidity (>80 %) the ambient temperature must not 40 °C (+104 °F).
The polyester films must not come in contact with benzyl alcohol or methylene
chloride.
Safety Instructions
W
12
Gateway 0362151A - PROFIBUS to SERVOLINK 4 Safety
2
Содержание 036215
Страница 1: ...Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety P TD 0000331 12 2019 04 09 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety ...
Страница 16: ...Safety Instructions W 16 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 2 ...
Страница 18: ...Unit Assembly Complying EMC W 18 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 3 ...
Страница 26: ...Gateway 0362151A W 26 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 4 ...
Страница 28: ...Mounting and Demounting W 28 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 5 ...