Code
Description
Course of action
For gateway error: Send the gateway to
SIEB & MEYER.
E.23.
Hardware error at ZERO
Check the signal lines.
Check the supply lines for interference
pulses.
For gateway error: Send the gateway to
SIEB & MEYER.
E.24.
Reserved for special software
Depends on the used software
E.25.
Reserved for special software
Depends on the used software
E.26.
Reserved for special software
Depends on the used software
E.27.
Reserved for special software
Depends on the used software
6.3.3
LED Status Display (Drives)
Each drive has a multi-colored status LED at
the front panel that indicates the status of the
drive monitorings.
Switch-on
In order to check their functionality all drive LEDs are set to the following states (one
after the other) during switch-on:
1. status LED on/red for 2 seconds
2. status LED on/green for 2 seconds
3. status LED off for 2 seconds
Afterwards switch-on is continued according to the selected operating mode (MODE
switch position).
Operating mode: Normal operation
During normal operation each drive LED can have the following states.
Color
Status
Meaning
–
Off
No monitoring is active for the drive.
Red
On
Heartbeat monitoring has triggered an error (error E.05.).
PLC sends zero data telegrams (error E.10.).
Yellow
On
Speed zero monitoring has detected motor standstill.
Green
On
Motor is possibly running.
Operating mode: Configuration speed zero monitoring
During configuration of speed zero monitoring with OSSD signals each drive LED can
have the following states.
Color
LED status
Meaning
–
Off
No monitoring is active for the drive.
Red
Flashes
Speed zero monitoring with OSSD signals is selected.
W
Connectors, Switches and Displays
Gateway 0362151A - PROFIBUS to SERVOLINK 4 Safety
39
6
Содержание 036215
Страница 1: ...Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety P TD 0000331 12 2019 04 09 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety ...
Страница 16: ...Safety Instructions W 16 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 2 ...
Страница 18: ...Unit Assembly Complying EMC W 18 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 3 ...
Страница 26: ...Gateway 0362151A W 26 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 4 ...
Страница 28: ...Mounting and Demounting W 28 Gateway 0362151A PROFIBUS to SERVOLINK 4 Safety 5 ...