SR882 operation manual
~ 47 ~
output is switched-off
►Press “ESC” to exit P1 set program
-----------------------------------------------------------------------------------------------------------------
►Press “SET” button, “HND2 off” displays on the
screen, P2 output manually set
►Repress “SET” button, “HND2 on” displays on the
screen, P2 output is switched-on
►Repress “SET” again, “HND2 off” displays, P2
output is switched-off
►Press “ESC” to exit P2 set program
-----------------------------------------------------------------------------------------------------------------
►Press “SET” button, “HND3 off” displays on the
screen, H1 output manually set
►Repress “SET” button, “HND3 on” displays on the
screen, H1 output is switched-on
►Repress “SET” again, “HND3 off” displays, H1
output is switched-off
►Press “ESC” to exit H1 set program
---------------------------------------------------------------------------------------------------------------
Note:
when manual mode is activated
,
signal displays on the screen, after 15 minutes
all outputs are switched-off, controller exits manual mode automatically.
4.12 REST Recovery to factory set
Setup steps:
To access main menu REST,
►Press “SET” button, “YES” displays on the screen.
►Hold down “SET” button, buzzer makes “du-----“ 3
times, then release
“SET” button and wait for display recovery to initial interface, that means
controller recovers to factory set, new paramters can be reset now.
►Press “ESC” button to exit set program or wait for 20 seconds to exit automatically.
4.13 PASS Password set
Setup steps:
To access main menu PASS,