SR882 operation manual
~ 17 ~
2.6 System description
Note:
T3 is alternative sensor, when no sensor (T3) is installed on the top part of tank, controller
will use the signal of sensor T2 automatically to control the auxiliary heating or the
circulation pump.
1 collector array
– 1 storage tank – 1 pump and auxiliary heating
Description:
The solar circuit pump (P1) is switched on as soon as the switch-on temperature difference
(
△
Ton) between the collector array (T1) and the storage tank (T2) is reached. If the
temperature difference between the collector array (T1) and storage tank (T2) drops below
the switch-off temperature difference (
△
Toff), or the temperature of storage tank (T3)
reaches the preset maximum storage temperature, then the solar circuit pump (P1) is
switched off.
Back-up heating by auxiliary boiler
(detailed see paragraph 3.2):
Within the preset schedule of back-up heating, if the temperature T3 is below the preset
switch-on temperature, then the back-up heating
(
H1
)
is triggered, when T3 is heated to
the preset switch-off temperature, back-up heating H1 is ceased.
T1: Sensor on collector array
T2: Sensor on the bottom part of tank.
T3: Sensor on the top part of tank
(optional sensor)
T4: Sensor on hot water pipe, on solid
fuel boiler or for thermostat (alternative)
T5: Sensor on tank return pipe (for
measuring thermal energy)
T6: Sensor on tank flow pipe
P1: Solar circuit pump
P2: Hot water circuit pump, solid fuel boiler circuit pump, output for thermostat or output for
high temperature cooling (Note: this output can only used as one of above mentioned four
functions, depend on which function is activated)
H1: Output for back-up electrical heater