SR882 operation manual
~ 44 ~
2 application examples:
Release energy from tank Heat tank to constant temperature
Setup steps:
To select
menu AHO, “AHO ----” displays on the screen.
►Press “SET” button, parameter “----”blinks. Factory set
“-----”.
►Repress “SET” button, to activate this function, and
parameter “50
o
C
”blinks on the screen.
►Press “+” “-” button to adjust switch-on temperature of
thermostat function, adjustable range (2
~
95
o
C
)
►Press “ESC” button to exit menu.
►Press “+” button, “AHF 55
o
C
” displays, parameter “55
o
C
” blinks, and factory set “55
o
C
”
► Press “+” “-” button to adjust switch-off temperature of
thermostat function, adjustable range (2
~
95
o
C
)
►
Press
“SET” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.
Signal blinks on the screen, it indicates AHO function is activated.
Note: when one of functions AHO, COOL, CIRC, SFB is activated, then the rest 3
functions will be automatically deactivated.
4.9 OSDC SD card data save function
Description:
Put the SD card in the groove, data is logged immediately. Then under menu of the OSDC
card,
“OSDC ON” displays automatically, it means data is logging, the interval of data log
can be set. If card is full, then data logging is stopped, and CFULL displays on the screen.