SR882 operation manual
~ 22 ~
Application Example
:
1 2 3
If customer use electrical heater as back-up, please according to the power of electrical
heater to equip corresponding safety devices like contactor and breaker with this controller,
we strongly recommend equipping with SR802 device with this controller, (SR802 detailed
technical data see paragraph spare parts)
3.3 CIRC DHW pump control function
Select CIRC
submenu, “CIRF OFF” appears on the
screen, the default set is: OFF.
► Press “SET” button, parameter “OFF” blinks on the
screen.
► Repress “SET” button to activate this function, “CIRC
ON
” appears on the screen.
►Press “ESC” to exit this submenu, or wait for 20
seconds to exit automatically, the parameter valves are
saved automatically.
► Press “+” button, “tCYC” appears on the screen.
► Press “SET” button to access “tCYC” menu.
► Press “SET” button, access tCYC three schedules
function,
“tC 1o 05:00”appears, now can set the first
turn-on time.
► Press “SET” button again, “05” of hour time blinks on
screen.
►Press “+” “-” button to adjust hour of time.
►Repress “SET” button, “00” of minute time blinks on
screen.
►Press “+” “-” button to adjust minute of time.
►Repress “SET” button, “03 Min” of pump running time