LED indicator/fault pattern /
LED indicator/fault pattern
Cause /
Cause
Measures /
Measures
sensing range and adjust if
necessary; see graphic H. /
With health output: Check the
power supply, check all electri‐
cal connections (cables and
plug connections).
Yellow LED lights up, no object
in the path of the beam /
Yellow LED lights up, no object
in the path of the beam
The beam of light of a photo‐
electric through-beam sensor
hits the receiver of another
(neighboring) photoelectric
through-beam sensor /
The beam of light of a photo‐
electric through-beam sensor
hits the receiver of another
(neighboring) photoelectric
through-beam sensor
Swap the sender and receiver
arrangement at every se‐
cond photoelectric through-be‐
am sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors /
Swap the sender and receiver
arrangement at every se‐
cond photoelectric through-be‐
am sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors
8
Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regulati‐
ons. Efforts should be made during the disposal process to recycle the constituent ma‐
terials (particularly precious metals).
9
Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
8
8017857.YMH6 | SICK
Subject to change without notice