Additional notes:
•
Max. 0.5 A output for supply voltage connections (compliant with LPS)
•
Frequency: max. 2 MHz
•
TTL encoders use RS-422 and can be connected via the INC interface.
6.5.4
CAN
1
4
3
5
2
Table 5: CAN pin assignment, M12 - 5-pin A-coded, female
Pin
Signal
Function
Factory settings
1
-
Screen
-
2
+V24
Supply voltage for
peripherals, configura‐
ble
Deactivated
3
GND
Ground
-
4
CAN_H
CAN high
Termination deacti‐
vated
1)
5
CAN_L
CAN low
Housing
-
Screen
-
1)
Termination can be controlled via app
Additional notes:
•
Max. 3.2 A output for supply voltage connections (compliant with LPS)
•
To enable voltage supply to the peripherals, both voltage supply strands of the
POWER connection must be connected to 24 V.
6.5.5
SENSOR 1-6
1
4
3
5
2
Table 6: SENSOR 1-6 pin assignment, M12 - 5-pin, A-coded, female
Pin
Signal
Function
Factory settings
1
+24 V
Supply voltage for
peripherals, configura‐
ble
Deactivated
2
Input 2
Digital input
-
3
GND
Ground
-
4
C/Q or Input 1/Output
1
C/Q IO-Link or con‐
figurable digital input/
output
All IO connections con‐
figured as inputs
5
NC
Not connected
-
Housing
-
Screen
-
ELECTRICAL INSTALLATION
6
8023514/1CC6/2021-07-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | SIM1012
19
Subject to change without notice