Additional notes:
•
6 x IO-Link master (1x master available per connection)
•
The digital inputs and outputs are only switchable if the supply voltage is activated
on pin1, or +24 V is externally applied to pin1. A ground connection on Pin3 is
required in both cases.
•
Digital output:
°
Max. output 100 mA
°
Min. high output logic level: VCC – 3 V
°
Max. low output logic level: 3 V
°
Push-pull switch
°
Max. IO-Link output frequency: 230 kHz
°
Max. IO output frequency: 30 kHz
•
Digital inputs:
°
Min. high input logic level: 12 V
°
Max. low input logic level: 4 V
°
Max. IO-Link input frequency: 230 kHz
°
Max. IO input frequency: 30 kHz
•
Max. 1 A output for supply voltage connections S1 to S6 (compliant with LPS)
•
HTL encoders use push-pull switches and can therefore be connected via the
digital inputs.
Recommendation when using S1 to S6 for illumination
Short flash times can be achieved by using an illumination unit with signal strobe and
by using pin4 as a digital output signal with a constant supply voltage on pin1 (Signal
Strobe Mode).
The SIM1012
does not
support Power Strobe Mode via the "Connector.Power.Gate” API.
6.5.6
ETH1 – ETH2
1
7
2
6
5
4
3
8
Table 7: ETH1 - ETH2 pin assignment, M12 - 8-pin X-coded, female
Pin
Function
1
D1+
2
D1-
3
D2+
4
D2-
5
D4+
6
D4-
7
D3-
8
D3+
Additional notes:
The Ethernet connections can be used to connect to picoCam and midiCam family
cameras and SICK LiDAR sensors as well as a PC or network.
The relevant drivers are implemented in the SIM1012 to enable usage of the SICK
picoCam and midiCam camera families.
6
ELECTRICAL INSTALLATION
20
O P E R A T I N G I N S T R U C T I O N S | SIM1012
8023514/1CC6/2021-07-28 | SICK
Subject to change without notice