Important:
•
Up to and including SIM1012 firmware version 1.x.x, only first generation picoCam
and midiCam cameras are supported.
•
For SIM1012 firmware version 2.x.x and above, only picoCam2 and midiCam2
cameras as well as third party GigE Vision compatible cameras are supported.
Jumbo frame support is needed when using Ethernet switches.
Transmission rate: max. 1 Gb/s
6.6
Connecting peripheral devices
The device can be connected to a wide range of sensors and cameras.
The required pin assignments can be found in the data sheets for the peripherals to be
connected as well as in the relevant connection descriptions,
.
1.
Connect the cables to peripheral devices.
2.
Route the cables to the device using installation materials (cable channels, cable
ties, etc.). When doing so, pay attention to cable strain relief.
3.
Connect cables to the relevant device connections and screw together tightly.
4.
Seal unused connections with dummy plugs.
6.7
Connecting voltage supply
NOTICE
Risk of damage to peripheral devices!
If peripheral devices are connected when the voltage supply is also applied, these
devices can become damaged.
■
Only connect peripheral devices when the voltage supply is disconnected.
1.
Ensure that the voltage has been disconnected by the user.
2.
Connect voltage supply cable(s) to the device.
3.
Lay the cable(s) with strain relief.
4.
Have the user connect the voltage supply.
5.
Have the user activate the voltage.
ELECTRICAL INSTALLATION
6
8023514/1CC6/2021-07-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | SIM1012
21