6
Up to 20 m: Working range for objects with 1 m
2
RCS (typical radar cross section for a
person)
7
Up to 45 m: Working range for objects with 10 m
2
RCS (typical radar cross section for a
person)
10.2
Performance
Initialization time
≤
15 s
Update rate
≤
60 ms
Integrated application
Field evaluation
Number of field sets
Up to 6 fields
10.3
Interfaces
Ethernet
✓
Function: configuration, data output
CANopen
In progress
Digital inputs
2 (electrically isolated from the supply voltage , U
e
= max. 36 V DC,
I
e
= max. 5 mA, opto-decoupled, reverse polarity protected,
adjustable debounce time)
Digital outputs
4 (not electrically isolated from the supply voltage, PNP/NPN/PP
configurable, U
a
= U
V
- 1.5 V DC, I
A
≤ 100 mA (typical), short-circuit
protected, temperature protected)
10.4
Mechanics/electronics
Connection type
1 x M12 male connector, 8-pin, A-coded
1 x M12 male connector, 5-pin, A-coded
1 x M12 female connector, 4-pin, D-coded
Supply voltage
9.5 V DC … 36 V DC
ES1, energy-limited circuit in accordance with UL/IEC/EN 61010-1
or Class 2 (NEC, UL1310)
Power consumption
≤
21 W (with a typical load of the 4 digital outputs of 100 mA and
36 V DC supply voltage)
< 6 W (typical, without digital output load)
Housing
Aluminum
Housing color
Blue
Enclosure rating
IP67 (EN 60529: 1991-10/A2: 2000-02)
1
Protection class
III (EN 61140:2006-08)
Electrical safety
EN 62368-1 (2014-08)
Weight
500 g
Dimensions (L x W x H)
85 mm x 97 mm x 60.75 mm
1
In connected state with suitable mating plug or protective cap mounted on the connections
TECHNICAL DATA
10
8021530/19JS/2021-02-09 | SICK
O P E R A T I N G I N S T R U C T I O N S | RMS3xx