OUT1
OUT4
OUT3
OUT2
GND
IN2
IN1
+24 V
Power
5
4
3
2
1
CAN I/0
8
7
6
5
4
3
2
1
CAN H
CAN L
IN2
Figure 3: NPN outputs connection example
6.4
Connecting the device electrically
1.
Ensure the voltage supply is not connected.
2.
Connect the device according to the connection diagram,
.
3
2
1
Figure 4: RMS3xx connection overview
1
Ethernet
2
CAN I/O
3
Power
3.
Switch on the supply voltage.
✓
The initialization phase starts, the Power LED lights up yellow. As soon as the
Power LED lights up green, the device is ready for operation.
ELECTRICAL INSTALLATION
6
8021530/19JS/2021-02-09 | SICK
O P E R A T I N G I N S T R U C T I O N S | RMS3xx
17