7.4.5.2
Hold function
Measured value
Hold the measured value that is present at the hold input signal (rising edge).
ON
OFF
1
2
HOLD
1
Measured value
2
Output hold value (sample hold value)
Peak value
Hold the largest measured value that is present in the time interval between the last
falling edge and the hold input signal (next rising edge).
ON
OFF
1
2
3
HOLD
1
Measured value
2
Output hold value (peak hold value)
3
Interval in which an analysis is carried out.
Lowest value
Hold the lowest measured value that is present in the time interval between the last
falling edge and the hold input signal (next rising edge).
ON
OFF
1
2
3
3
HOLD
1
Measured value
2
Output hold value (bottom hold value)
3
Interval in which an analysis is carried out.
Peak-to-peak value
Hold the differential value between the smallest and the largest measured value
present in the interval between the last falling edge and the hold input signal (next
rising edge).
7
OPERATION
42
O P E R A T I N G I N S T R U C T I O N S | OD2000
8026231//2021-11-17 | SICK