Minimum
1
Maximum
3
4
1
0
2
Figure 16: Object between device and background (N/C contact: Low-active, PNP)
1
Minimum
2
Tolerance around switching point
3
Maximum
4
Switching point (reference background)
Selecting output mode and setting parameters
>
Q1 Output
>
>
Q1 Mode
>
>
Q1 Window (SP1:ObSB)
>
>
Q1 Output
>
> Parameter >
> Select option, teach-in or set value >
Parameter
Value
Factory setting
Q1 SP1 teach-in (auto)
OD2000-
030
:
-5.04 mm ... +5.75 mm
OD2000-
050
:
-10.10 mm ... +11.50 mm
OD2000-
245
:
-176.75 mm ... +189.00 mm
OD2000-
350
:
-252.50 mm ... +271.00 mm
OD2000-
700
:
-505.00 mm ... +550.00 mm
0.00 mm
Q1 SP1 teach-in (manual)
Q1 Switch point logic
High-active
Low-active
High-active
Q1 Timer mode
Off
Switch-on delay
Switch-off delay
Switch-on/off delay
Pulse (one shot)
Off
Q1 Timer setup
1 ms ... 30,000 ms
1 ms
Q1 Hysteresis
0 mm ... 2,147.48 mm
OD2000-
030
: 0.1 mm
OD2000-
050
: 0.2 mm
OD2000-
245
: 0.5 mm
OD2000-
350
: 1 mm
OD2000-
700
: 1.5 mm
Q1 Tolerance
0 mm ... 2,147.48 mm
OD2000-
030
: 1 mm
OD2000-
050
: 1 mm
OD2000-
245
: 4 mm
OD2000-
350
: 4 mm
OD2000-
700
: 4 mm
7.4.3.5
Output mode alarm
As long as no measurement is possible, a constant switching signal is issued at the
output. This function can be used, for example, to evaluate the measured value at the
analog output.
OPERATION
7
8026231//2021-11-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD2000
35