Parameter
Value
Factory settings
Q1 SP1 teach-in (auto)
OD2000-
030
:
-5.04 mm ... +5.75 mm
OD2000-
050
:
-10.10 mm ... +11.50 mm
OD2000-
245
:
-176.75 mm ... +189.00 mm
OD2000-
350
:
-252.50 mm ... +271.00 mm
OD2000-
700
:
-505.00 mm ... +550.00 mm
SP1: 0.00 mm
Q1 SP1 teach-in (manual)
Q1 SP2 teach-in (auto)
SP2:
OD2000-
030
: +5 mm
OD2000-
050
: +10 mm
OD2000-
245
: +175 mm
OD2000-
350
: +250 mm
OD2000-
700
: +500 mm
Q1 SP2 teach-in (manual)
Q1 Switch point logic
High-active
Low-active
High-active
Q1 Timer mode
Off
Switch-on delay
Switch-off delay
Switch-on/off delay
Pulse (one shot)
Off
Q1 Timer setup
1 ms ... 30,000 ms
1 ms
Q1 Hysteresis
0 mm ... 2,147.48 mm
OD2000-
030
: 0.1 mm
OD2000-
050
: 0.2 mm
OD2000-
245
: 0.5 mm
OD2000-
350
: 1 mm
OD2000-
700
: 1.5 mm
7.4.3.4
Window output mode (SP1:ObSB)
Set a background as a reference. If the reference background is not detected (nor‐
mally open contact:
High-active
switching point logic) or if the reference background is
detected (normally closed contact:
Low-active
switching point logic), a signal is output. In
the ObSB output mode, all objects deviating from the background are detected. Objects
that are reflective or black are also detected.
Minimum
1
Maximum
3
4
1
0
2
Figure 15: Object between device and background (N/O contact: High-active, PNP)
1
Minimum
2
Tolerance around switching point
3
Maximum
4
Switching point (reference background)
7
OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | OD2000
8026231//2021-11-17 | SICK
Subject to change without notice