Operating Instructions
LMS1xx Laser Measurement Sensors
Product description
8012471/ZN27/2017-06-09
© SICK AG · Germany · All rights reserved · Subject to change without notice
41
Chapter
3
3.9.1
Evaluation cases
An evaluation case defines which output field is evaluated in which way and on which output
it acts. You can configure up to ten evaluation cases, all configured evaluation cases are
active simultaneously.
For each evaluation case you configure in SOPAS ET:
inputs that activate an evaluation case, if necessary
the evaluation strategy
the evaluation field
the output on which the evaluation case acts
the response time of the output
P
ROJECT
TR
ee, LMS…, P
ARAMETER
, E
VALUATION
CASES
.
Inputs
If the evaluation case is not to be permanently active, then you can configure an input
combination to activate the evaluation case.
Wichtig
An input combination can also be defined for several evaluation cases, e.g. two evaluation
cases will then be active simultaneously.
LMS12x/LMS13x/LMS14x Security and LMC12x/LMC13x VdS (object protection)
You will find the input conditions for these devices in the document ”Technical Information
(installer instructions VdS)”, part no.: 8013749, issue in English.
Please see
section 1.5 “Further information” on page 9
Input 1
Input 2
Evaluation case
Active high
Active high
Evaluation case 1
Active high
Active low
Evaluation case 2
Active low
Active high
Evaluation case 3
Active low
Active low
Evaluation case 4
Tab. 11:
Input combination examples LMS10x/LMS11x/LMS15x