Product description
20
© SICK AG · Germany · All rights reserved · Subject to change without notice
8012471/ZN27/2017-06-09
Operating Instructions
LMS1xx Laser Measurement Sensors
Chapter
3
3.4
Special features of the LMS1xx
LMS12x/LMS13x/LMS14x Security and LMC12x/LMC13x VdS (object protection)
You will find further information on the special features of these devices in the document
”Technical Information (installer instructions VdS)”, part no.: 8013749, issue in English.
Please see
section 1.5 “Further information” on page 9
Variant
Special features
All
Field of view maximum 270°
Resolution of the angular step width: 0.25/0.50°
Scanning frequency 25/50 Hz
Flexible system configurations
Configuration/measured value request using telegrams (command strings)
2 digital switching inputs
Data interfaces Ethernet, RS-232, CAN (for the connection of an I/O module)
Measured value output (raw data)
electro-sensitive, active measurement technique
measurement of objects with almost any shape
measured value output for a second reflection pulse (e.g. in rain or on measurement through a window)
Integrated field application
Up to 10 configurable evaluation fields (depends on LMS1xx variant)
Monitoring of the evaluation field contours
Switching of the evaluation fields using digital switching inputs
Encoder inputs (not for LMS12x/LMS13x/LMS14x)
Additional output of the evaluation field (unoccupied or infringed) via switching outputs or telegrams
LMS10x
Scanning range up to 20 m with > 13 % object remission (18 m with 10 % object remission)
Indoor housing with protection class IP 65
3 digital switching outputs
LMS11x
Scanning range up to 20 m with > 13 % object remission (18 m with 10 % object remission)
Outdoor housing with protection class IP 67
3 digital switching outputs
LMS12x
LMS173
Scanning range up to 20 m with > 13 % object remission (18 m with 10 % object remission)
Indoor housing with protection class IP 65
Optimized for usage in object protection systems
2 additionally digitale switching inputs
Relay switching outputs
Digital sabotage output
LMS13x
LMS182
Like LMS12x, however
Outdoor housing with protection class IP 67
LMS14x
Like LMS12x, however
Scanning range up to 30 m with > 10 % object remission
Outdoor housing with protection class IP 67
Optimized for usage in object protection systems
Relay switching outputs
LMS14x Core: the device sends the measured contour values via RS-232/Ethernet only with low refresh rate. The
data can only be used for visualization and configuration on the PC.
LMS15x
Like LMS11x, however
Scanning range up to 50 m with > 75 % object remission (18 m with 10 % object remission)
Tab. 9:
Special features of the LMS1xx variants