3.3
Mechanical installation
3.3.1
Preparations
The following tools and materials are required to install the FLOWSIC30:
● Hoisting equipment (lifting capacity according to the weight specifications on the type
plate),
● Box wrench with size suitable for flange installation,
● Torque wrench,
● Flange gaskets,
● Bolt lubricant,
● Leak detection spray.
3.3.2
Meter orientation
1)
Horizontal position of ultrasonic sensors must not deviate by more than ±3°
2)
Only for dry gas
A
Horizontal, electronics up
B
Vertical
C
Horizontal, electronics down
D
Horizontal, electronics at side
1)
2)