2.6
Data processing in FLOWSIC30
2.6.1
Event logbook
The FLOWSIC30 stores events and parameter changes in the event logbook. All events are
saved with time stamp, user logged on and totalizer reading. The event logbook can be
accessed via HART
®
or the FLOWgate
TM
operating software. A list of the last 30 events is
displayed via HART
®
. All events can be accessed via the FLOWgate
TM
operating software.
2.6.2
Diagnostic archive
Diagnostic data are saved in cyclic intervals in the diagnostic archive.
Dataset number, timestamp, various global measured values, status information and path
information are saved. The archive has a capacity of more than 40,000 entries and is
circulating by default. The archive serves primarily for analysis of historical measured data.
2.7
Display and operating elements
The measured values shown on the LC display of the SPU can be defined using the
FLOWgate
TM
operating software or via HART
®
access. Up to ten measured values can be
defined which are shown on the display alternating. They embrace the most often
industrially used parameters.
If an event occurred the event is displayed alternating with the measured values. When in
configuration mode, the display will also show the message: “I-1013 config mode”
Fig. 5
LCD FLOWSIC30
FPC
FLOWSIC 30
FLOWSIC 30
1
1 Symbol bar
2 Measured values
2