START-UP AND PARAMETER SETTINGS
Enter the regression coefficients
There are two options:
– Direct input of K2, K1, K0 in a measured value computer.
– Use the regression function of the measuring system (use without measured value
computer). In this case, the correlation to the scattered light intensity has to be deter-
mined. To do this, calculate the regression coefficients cc2, cc1, cc0 to be entered in
the measuring system from K2, K1, K0.
Using (2) in (1), the result is as follows:
Using (3), the result is as follows:
Now enter the regression coefficients cc2, cc1 and cc0 determined in directory “Configu-
ration/Application parameters” (
see “Assigning the sender/receiver unit to the measuring
location (in SOPAS ET)”, page 60
) (set sender/receiver unit to “Maintenance” state and
enter the Level 1 password).
Reset the sender/receiver unit back to “Measurement” state afterwards).
NOTE:
In this case, the regression coefficients set in the sender/receiver unit and the
measuring range set in the MCU may not be changed anymore. On the optional
LC Display (when used), the dust concentration is displayed as uncalibrated
value in mg/m³.