20
8012426/YWL2/3-0/2016-08| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER SP100
Subject to change without notice
2
PRODUCT DESCRIPTION
2.2.2
Flange with tube
The flange with tube is available in different steel grades and dimensions (
). Selection depends on the wall and isolation thickness of the duct wall
(
→
nominal length) and the duct material.
Fig. 8: Flange with tube
TOP
Material St 37 or
1.4571
NL
Gas
temperature
Sender/receiver unit nominal length (in mm)
435
735
1035
1335
< 150
°
C
130, 240
130, 240, 500
800
1100
NL (in mm)
> 150
°
C
240
500
240
Standard version
for internal duct pressure > +50 hPa
Marking for assembly position
Securing bolt