PRODUCT DESCRIPTION
2
2.2.3
MCU control unit
Control unit MCU has the following functions:
●
Control of the data traffic and processing of the sender/receiver unit data connected via
the RS485 interface
●
Signal output via analog output (measured value) and relay outputs (device status)
●
Signal input via analog and digital inputs
●
Power supply for the connected measuring unit via 24 V switch-mode power supply with
wide range input
●
Communication with higher level control systems via optional modules
Equipment and device parameters can be set easily and conveniently via a USB interface
using a PC and a user-friendly operating program. The parameters are stored reliably even
in the case of a power failure.
Control unit MCU has a sheet steel enclosure as standard.
2.2.3.1
Standard interfaces
Analog output
Analog inputs
Relay outputs
Digital inputs
Communication
3 outputs 0/2/4...22 mA
(electrically isolated,
active) to output:
●
Scattered light intensity
(corresponds to the
uncalibrated dust con-
centration),
●
Dust concentration,
calibrated
●
Dust concentration,
scaled
Resolution 10 bits
2 inputs 0...20 mA
(standard; without
electric isolation);
resolution 10 bits
5 changeover
contacts (48 V, 1 A)
to output status
signals:
●
Operation/failure
●
Maintenance
●
Function check
●
Maintenance
request
●
Limit value
4 inputs to connect
potential-free contacts
(e.g. to connect a
maintenance switch,
trigger a function
check or more error
messages)
●
USB 1.1 and
RS232 (on termi-
nals) for measured
value inquiries,
setting parameters
and software
updates.
●
RS485 for sensor
connection