LIFT TABLE CALIBRATION
1. Turn the lift off.
2. Set dip switch 4 to ON
3. Turn the lift on
4. Wait 2 seconds then set dip switch 4 to OFF.
5. Move the lift to the CAL LT 0 point (lift table closed), then press the button on the board.
5.1 Move the lift to the CAL LT 1 point, lift table opened and mechanical safety device
in proximity of the last tooth on the top and then press the key P1 on card.
6. Wait for the message “CALIBRATION OK”, then turn the lift off. The integrated lift
table is now calibrated.
dip-sw 4
P1
4
REMARKS:
The integrated lift table (LT) is disabled if it has not been calibrated.