e005 OLIMPO
ver. 00
User’s manual
pag. 20 di 29
Printed in
e005-di OLIMPO (eng).doc
Siap+Micros S.r.l.
where:
ST02
Station n°2
STid_station
6
Constant code of the record format with a
dynamic structure
6
13.45
The
hour
and
minute
of the event
hh.nn
04
The
day
of the event
gg
02
The
month
of the event
mm
96
The
year
of the event
aa
2
Constant code identified by the D
ata in Alert
2
M01
Means that 1 block which follows represents 1 parameter
Mnum_input
10
The ID of the parameter in alarm
id
T
Specifies that the following field is that type of parameter
constant
0
An
analogic
type of parameter
value
W
Indicates that the following field is the
type of alert
of the parameter
constant
2
Maximum alert
value
A
Specifies that the following field is of I
nstant Data
of the parameter in
alert
constant
13.5
The I
nstant Data
of the parameter in alert
value
V
Specifies that the following field is the
alert threshold
of the
parameter
constant
10
The
alert threshold
of the parameter
value
#18
Terminator
terminator
N.B.:
The format used is the same used to record the data without any notes.