background image

 

 

e005 OLIMPO 

 

 

ver. 00 

 
 

 
User’s manual 

pag. 10 di 29 

Printed in 

e005-di OLIMPO (eng).doc 

 

Siap+Micros S.r.l. 

1.15 

Record format for 

Statiscal Data 

The S

tatistical Data

  is available with this format in File n° 

6

 (internal memory) or in the File n° 

10

 (memory 

card). 

1.15.1 HAED 

The 

Head  of  the  Record  Format 

contains  the  information  which  allows  for  the  identification  of  the  record 

based on the event of a storm and of the station of origin. Its format in detail is as follows: 

 

ST

id_station

 , 6 , hh.nn.ss , gg , mm , aa , 0 , M

num_input 

the meaning of the various fields is summarized in the following table: 

 

STid_station 

A Header which identifies the beginning of the 

Head

 of the record. It is composed of 

"ST" characters plus a number which indicates the code (ID) of the station. 

For example the 

Header 

STO1

 identifies the record of station 

1

A constant code which identifies three record format of the 

Dynamic Structure

hh.nn.ss 

Hour,  minute  and  second  of  the  event  in  the  following  format: 

hh.nn.ss

.  As  an 

alternative since we are dealing with 

Statistical Data

, it is possible to use the 

hh.nn

 

format. 

gg 

Day of the event memorized in the record with the 

:gg

 format

.

 

mm 

Month of the event memorized in the record with the 

:mm

 format

.

 

aa 

Year of the event memorized in the record with the 

:aa

 format

.

 

A constant code which identies this type of  record Format for the 

Statistical Data

Mnum_input 

A  header  which  identifies  the  end  of  the 

Head

  of  the  record.  It  is  composed  of  the 

character  "M"+  a  number  indicating  the  total  number  of  parameters  (analogic  input 
and/or the digital ON/OFF) held in the 

Body

 of the  record format. 

For example M9 indicates the total of 9 parameters, whereas M50 indicates a total of 
50 parameters. 

 

1.15.2 BODY 

The 

Body

  of  the 

Record  Format

  contains  the 

Statistical  Data

  (average,  minimum,  maximum,  standard 

deviation,  standard,  variation  etc)  regarding  every  parameter  of  measurement.  The 

Body 

of  three  record  

format  is  therefore  the  repetition  of  a  block  of  information  which  has  been  repeated  as  many  times  as  the 
parameters it represents. 

Especially the format of the 

Body

 is as follows: 

 

RECORD BODY = b “,” + b “,” + b ...... 

 

Each  block  is  composed  of  several  sections  which  altogether  make  up  the  anagraph  of  the  parameter 
represented. The block has a  

dynamic structure

, so there can be many 

sections

 which represent it. In the 

specific case of thee S

tatistical Data

, there is not a fixed number of sections, but these may vary according to 

precise necessities. 

Each block is structured like this : 

 

BLOCCK_1 = id +  “,”  + constant  + “,” + value 

 

Содержание e005 OLIMPO

Страница 1: ...MPO Data Collection Unit User s Manual ver 5 12 SIAP MICROS S r l Via del Lavoro 1 tel 39 0438 491411 fax 39 0438 401573 I 31010 Castello Roganzuolo email info siapmicros com di San Fior TV www siapmi...

Страница 2: ...10 3 Configuration of the parameters 6 1 11 Acquisition cycle 6 1 12 The registration 7 1 13 The registration autonomy 8 1 14 Substitution of the MEMORY CARD 8 1 14 1 Data format 8 1 15 Record format...

Страница 3: ...he unit should be connected to an electric earthing or of safety by using a three wired AC power cable This cable should be connected to Complied electric socket equipped with three contacts The unit...

Страница 4: ...g transport procedures we recommend that the unit be kept in an upright vertical position without shaking it 1 4 Unpacking Before unpacking the unit and installing it ensure that the following precaut...

Страница 5: ...n and where it can t damaged or moved due to inexperience or distraction Do not place any other objects or things which weigh more than a few kilograms on top of the unit Do not place the unit on top...

Страница 6: ...ser s manual pag 4 di 29 Printed in e005 di OLIMPO eng doc Siap Micros S r l 1 8 The panel description Display Membrane keyboard Memory card Red Led PWR COM1 RS232 Connection to PC PWR Switch COM2 RS2...

Страница 7: ...e SETUP procedures by pressing the button indicated as S as written on the display If no letters are digited the Olimpo Main Unit will carry out the preset acquisition procedures 1 10 Setup At any mom...

Страница 8: ...d on the display will appear Choose from the memory area to reset to zero by digiting the relative number 0 internal memory RAM and the memory card ATA internal memory RAM e memory card ATA 1 Internal...

Страница 9: ...3 5 Kbyte File 4 5 Kbyte File 5 5 Kbyte File 6 300 Kbyte File 7 1 Kbyte File 8 1 Kbyte File 9 1 Kbyte The acquired data taken by the Olimpo Main Unit are memorized on File 6 while the instant data ar...

Страница 10: ...wait for approx 10 15 seconds before verifying the acquisitions N B The insertion or the extraction of the MEMORY CARD without having switched off the unit could cause a malfunctioning of the Main Uni...

Страница 11: ...e data is recorded in the suitable memory area They are recorded in a sequence of characters ASCII The memorizing procedures of the data depend on the specific type of data in question These modules a...

Страница 12: ...event memorized in the record with the mm format aa Year of the event memorized in the record with the aa format 0 A constant code which identies this type of record Format for the Statistical Data Mn...

Страница 13: ...DEVIATION of the parameter identified by the field as id G VARIANCE of the parameter identified by the field as id H SUMMATION of the parameter identified by the field as id L MINUTE OF THE MINIMUM s...

Страница 14: ...nt Gg 02 Month of the event Mm 96 Year of the event Aa 0 The constant code identified by the Statistical Data 0 M03 Means that 3 Blocks which represent 3 parameters will follow Mnum_input 1 Id of the...

Страница 15: ...tant Data relating to every parameter of measurement The Body of the record format is therefore made up by repeating a block of information as many times as the parameters which are to be represented...

Страница 16: ...ht undertake and the next field value in the specific application of Instant Data constant the meaning the next field has undertaken value T TYPE analogic or digital of the parameter identified by the...

Страница 17: ...be structured like this id T value_1 A value_2 S value_3 The three sections shown do not have to be positioned in a precise order but it would be advisable to position as shown above Depending on the...

Страница 18: ...cates that the Instant data has been acquired correctly value 2 The ID of the second parameter id T Specifies that the next field is the type of the parameter constant 0 An analogic parameter value A...

Страница 19: ...2BODY The Body of the record format contains the Data in Alert regarding each parameter in alarm The Body of the record format is therefore composed of a repetition of a block of information which ha...

Страница 20: ...eld constant and the following field value might undertake in the special application of Data in Alert constant The meaning that the following field has undertaken value T TYPE analogic or digital of...

Страница 21: ...t have to be positioned in a precise order however it is advisable to position as shown above 1 17 3TERMINATOR Finally the terminator is a field which identifies the end of the record format The termi...

Страница 22: ...um_input 10 The ID of the parameter in alarm id T Specifies that the following field is that type of parameter constant 0 An analogic type of parameter value W Indicates that the following field is th...

Страница 23: ...outputs typical 4 20mA Resistive sensors Pt100 Sensors equipment with open contact outputs open closed ON OFF Sensors with impulse outputs counter frequency meters pluviometer anemometers etc Equipme...

Страница 24: ...risk analysis carried out described in the following pages the following European directives have emerged regarding this product Original Directive Directive with variations or additions Title Referen...

Страница 25: ...within the field of application of this present decree unless they are commercially available 3 The radio apparatus used by the amateur radio operators do not fall within the field of application of t...

Страница 26: ...for a correct use are Reference temperature 20 C Temperature of use 30 C 60 C Relative maximum humidity allowed 100 not condensed Storage temperature 30 C 70 C Storage humidity 90 Requested special tr...

Страница 27: ...have been applied and or technical specifications here below have been indicated CEI EN 61010 1 Safety regulation for electrical apparatus of measurement control and for laboratory use CEI EN 611131...

Страница 28: ...NE ALIMENTATORE 14 V KAT 600 MONITOR BATTERIA N N 12V BATTERIA 1 2Ah 1 2 4 6 5 3 PS CARICO BATT GND PS ALIM BATT ALIMENTAZIONE DISPLAY ALIMENTAZIONE OLIMPO ALIMENTAZIONE GSM SU PANNELLO FRONTALE INGRE...

Страница 29: ...mber of the station memorized on the Record format Refer to the software manual of OLIMPO SW for the running instructions of the station 1 2 Downloading instructions Turn off the OLM LMC Connect the c...

Отзывы: