e005 OLIMPO
ver. 00
User’s manual
pag. 16 di 29
Printed in
e005-di OLIMPO (eng).doc
Siap+Micros S.r.l.
where:
ST02
Station n°2
STid_station
6
The constant code of the record format with a
dynamic structure
6
13.45.15
Hour, minute and seconds
of the event
hh.nn.ss
04
The
day
of the event
gg
02
The
month
of the event
mm
96
The
year
of the event
aa
1
The constant code identified by the
Instant Data
1
M02
Means that 2 block represent 2 parameters
Mnum_input
1
The ID of the
first
parameter
id
T
Specifies that the next field is the
type
of parameter
constant
0
An
analogic
parameter
value
A
Indicates that the next field is the
Instant Data
of the parameter
constant
13.5
The
Instant Data
of the parameter with
id=1
value
S
Specifies that the next field is the
status
of the parameter
constant
0
Indicates that the Instant data
has been acquired correctly
value
2
The ID of the
second
parameter
id
T
Specifies that the next field is the
type
of the parameter
constant
0
An
analogic
parameter
value
A
Indicates that the next field is the
Instant Data
of the parameter
constant
*
Missing data
(impossible to acquire the data)
value
S
Specifies that the next field is the
status
of the parameter
constant
1
Indicates that the Instant data
has not been acquired correctly
due to an electrical error
value
#23
Terminator
terminator
N.B.:
the format used is which the data has been filed as , without any notes.
1.17 The record format of Data in Alert
The
Data in Alert
are available with this format in
file N°1
of the internal memory of OLIMPO D2T.
1.17.1 HEAD
The
Head
of the
record format
contains the general information which allows the record to be identified on
the basis of a storm event and on the station it belongs to. Its format is shown in detail below:
ST
id_station
, 6 , hh.nn.ss , gg , mm , aa , 2 , M
num_input
,