e005 OLIMPO
ver. 00
User’s manual
pag. 13 di 29
Printed in
e005-di OLIMPO (eng).doc
Siap+Micros S.r.l.
the meaning of the various fields is summarized in the following table
STid_station
A header which identifies the start of the
Head
of the record. It is composed of Letter
ST plus a number indicating the ID code of the station.
For example the
Header
STO1
identifies the record of station number
1
.
6
A constant code which identifies the record format in a
Dynamic
Structure
hh.nn.ss
The hour, minute and seconds of the event in a format of :
hh.nn.ss
gg
The day of the event memorized by the record in the format of:
gg
mm
The month of the event memorized by the record in the format of:
mm
aa
The year of the event memorized by the record in the format of:
aa
1
A constant code which identifies this type of record format for I
nstant Data
.
Mnum_input
A header which identifies the end of the
Head
of the record. It is composed of the
letter “M” plus a number indicating the total number of parameters (analogic input
and or the digital (ON /OFF) contained in
Body
of the record format.
For example M9 indicates a total of 9 parameters, while M50 indicates a total of 50
Parameters.
1.16.2 THE BODY
The
Body
of the
record format
contains
Instant Data
relating to every parameter of measurement. The
Body
of the record format is therefore made up by repeating a block of information as many times as the
parameters which are to be represented.
The format of the
Body
would show like this:
BODY RECORD = b “,” + b “,” + b......
Each block is composed of many sections which together make up the anagraph of the parameter
represented. The block has a
dynamic structure
, and so there can be many
sections
which represent it. In
the specific case of
Instant Data
, 3 sections are sufficient.
Each block would be structured like this:
BLOCK_1 = id + “,” + section _1 + “,” + section _2 + “,” + section_3
Herewith it is shown in detail where the various fields undertake the following meaning:
id
a numerical code which identifies in an univocal way the parameter (anologic input or
digital (ON/OFF) to which the following sections refer to.
sezione_1
Alphanumerical code composed by two fields containing one single information
regarding the parameter of measurement.
sezione_2
Alphanumerical code composed by two fields containing one single information
regarding the parameter of measurement.
sezione_3
Alphanumerical code composed by two fields containing one single information
regarding the parameter of measurement.
However, each section is divided into two fields which together compete to provide the single information
regarding the parameter. Each section is structured as shown:
SECTION_N = co “,” + value