1.
2.
VESA Standardized Mounting
The rear plate has 4 threaded holes for attaching the microphone to a VESA mounting device. The mounting holes follow the
VESA MIS-D standard:
Screw specification: M4 thread (hole depth = 9.15 mm)
Hole spacing: 100 mm square
The VESA mounting holes work with Shure's
accessories to mount the microphone on a pole.
Suspending from the Ceiling
Suspend the microphone using your own equipment, or with Shure's
(includes mounting cables and hooks).
To mount using your own equipment, you will need:
Braided metal cable or high-strength wire
Hardware to attach cable to ceiling
Attach the mounting cables to the 12
mm
diameter eyelet screws on the microphone.
Attach the cables to the ceiling using the appropriate hardware.
Hard Ceiling Mounting
You can mount square ceiling array microphones in hard ceilings without a tile grid using the A910-HCM accessory.