SHUR-DRI SDAS25-01 Скачать руководство пользователя страница 3

For parts or assistance, call SHUR-DRI Customer Service at 

1-800-535-4950

Installation / Operation

3

INSTALLATION

1. Install models SDAS25-01 and SDAS3-01 in a sump pit 

with a minimum diameter of 14" (356mm). Install model
SDVS3-01 in a sump pit with a minimum diameter of 
11" (280mm). Construct the sump pit of tile, concrete, steel
or plastic. Check the local codes for approved materials.
The pump should not be installed on clay, earth or sand sur-
faces. Clean the sump pit of small stones and gravel which
could clog the pump. Keep the pump suction housing clear
of debris.

2. Install the pump in the pit so the switch operating mecha-

nism has maximum possible clearance.

3. Install an in-line check valve to prevent flow backwards

through the pump when the pump shuts off.

4.

Install the discharge plumbing.

A. When using rigid pipe, use plastic pipe. Wrap the dis-

charge pipe thread with Teflon

TM

tape. Screw the pipe

into the pump discharge port hand tight +1 – 1-1/2 turns.

NOTICE: 

Do not use ordinary pipe joint compound on

plastic pipe. Pipe joint compound can attack plastics.

NOTICE:

Thread the discharge pipe into the pump body

carefully to avoid stripping or crossing threads.

B. If a flexible discharge hose is used, make sure the pump

is secured in the sump to prevent movement. Do not use
a flexible discharge pipe in any permanent installation. 

Risk of flooding. Can cause personal

injury or property damage.

Failure to secure pump may

allow pump movement, switch interference and prevent
pump from starting or stopping. 

NOTICE:

The discharge piping should be as short as pos-

sible to reduce pipe friction losses. Discharge pipe diam-
eter should be equal to or larger than the discharge size
of the pump. Smaller pipe diameters will restrict the
capacity of the pump and reduce pump performance. 

C. Secure the discharge line before starting the pump.

To reduce motor noise and vibrations, a short length of
rubber hose (e.g. radiator hose) can be connected into
the discharge line near the pump using suitable clamps.
If the pump discharge line is exposed to outside sub-
freezing atmosphere, the portion of the line exposed
must be installed so any water remaining in the pipe will
drain to the outfall by gravity. Failure to do this can
cause any water trapped in the discharge line to freeze
which could result in damage to pump.

5.

Power Supply:

This pump is designed for 115 V., 60 Hz.,

operation and requires a minimum 15 amp individual
branch circuit. Both the pump and switch are supplied with
3-wire cord sets with grounding-type plugs. The switch plug
is inserted directly into the outlet and the pump plug inserts
into the opposite end of switch plug.

Hazardous voltage. Can shock, burn or

cause death. 

Pump is supplied with a grounding conductor

and grounding-type attachment plug. To reduce the risk of
electric shock, be certain that it is connected only to a prop-
erly grounded, grounding type receptacle such as a ground-
ed water pipe or a properly grounded metallic raceway or
ground wire system. Ground terminal on pump cord plug is
provided for your protection. DO NOT REMOVE!
A ground fault circuit interrupter is recommended for use
with any electrical appliance submerged in water. For instal-
lation of such a circuit, consult a licensed electrician.

6. After the piping and the check valve (if needed) have been

installed, the unit is ready for operation

7. Check the operation by filling the sump with water and

observing pump operation through one complete cycle.

Risk of flooding. Can cause personal injury

and/or property damage.

Failure to make this operational

check may lead to flooding and premature failure.

OPERATION

Risk of electric shock. Shock can burn or kill.

Do not handle a pump or pump motor with wet hands or
when standing on wet or damp surface, or in water.
1. Keep the pump inlet screen clear.
2. The shaft seal depends on water for lubrication. Do not

operate the pump unless it is submerged in water as the
seal may be damaged if the pump is allowed to run dry.

3. The motor is equipped with an automatic reset thermal

protector. If the temperature in the motor should rise undu-
ly, the switch will cut off all of the power before any dam-
age can be done to the motor. When the motor has cooled
sufficiently, the switch will reset automatically and restart
the motor. If the protector trips repeatedly, the pump
should be removed and checked for the cause of the diffi-
culty. Low voltage, long extension cords, a clogged
impeller, very low head or lift, etc., could cause cycling.
Refer to the Troubleshooting Chart on Page 5 for additional
information.

4. Periodically inspect the pump, system components and

sump for debris and foreign objects. Keep the sump free of
all refuse. Perform routine maintenance as required.

Risk of flooding. Flooding can cause personal

injury or property damage.

This pump comes with the auto-

matic float switch mounted on the motor cover ready for oper-
ation. Do not change switch settings. Refer to the “Motor,
Switch & Cord Specifications” chart for switch settings.

Individual

Switch Setting

Model

Max.

Branch Circuit

Cord

in inches (mm)

Number

HP

Load Amps

Required (Amps)

Length

On      

Off

SDAS25-01

1/4

6.0

15

8’

10" (254)

3" (76)

SDAS3-01

1/3

10.0

15

8’

11" (279)

4" (102)

SDVS3-01

1/3

10.0

15

8’

7.5" (190)

2.5" (63.5)

MOTOR, SWITCH, & CORD SPECIFICATIONS

TM

E.I. DuPont de Nemours and Company Corporation.

Содержание SDAS25-01

Страница 1: ...D860 2 25 09 INSTALLATION MANUAL SUBMERSIBLE SUMP PUMPS Pages 2 6 FRENCH INSTALLATION MANUAL POMPES DE PUISARD SUBMERSIBLE Pages 7 11 SPANISH INSTALLATION MANUAL BOMBAS SUMERGIBLE DE SUMIDERO Pages 12 16 CONSUMER HOT LINE 1 800 535 4950 Monday Friday 7 30 AM to 5 PM CST SDVS3 01 ...

Страница 2: ...nt is only for use on 115 volt and is equipped with an approved 3 conductor cord and 3 prong grounding type plug Hazardous voltage Can shock burn or cause death To reduce the risk of electric shock pull the plug before servicing Pump is supplied with a grounding conduc tor and grounding type attachment plug Be sure it is connect ed only to a properly grounded grounding type receptacle Where a 2 pr...

Страница 3: ... directly into the outlet and the pump plug inserts into the opposite end of switch plug Hazardous voltage Can shock burn or cause death Pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a prop erly grounded grounding type receptacle such as a ground ed water pipe or a properly grounded metall...

Страница 4: ...er operation premature pump failure and flooding AIRLOCKS When a pump airlocks it runs but does not move any water An airlock will cause the pump to overheat and fail This pump has a small hole in the side of the pump housing See Figure 1 This is an anti airlock valve If you suspect an air lock insert a hat pin or a pipe cleaner into the anti airlock hole to clean out the debris To Replace the Ver...

Страница 5: ...ce float switch Pump won t shut off Defective float switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle in piping Float obstructed Remove obstruction Pump operates but Low line voltage If voltage under recommended minimum check size of wiring from main delivers little or no water switch on property If OK contact power company or hydro authority Worn or p...

Страница 6: ...pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period Models SD106 SD107 90 Days Models SDAS3 SDVS3 SDSU25 SD CUST 2 Years Model SDAS5 3 Years Pre Charge Water System Tank 5 Years Sewage Pump Model SDLTW50 Submers...

Страница 7: ... électricité en vigueur 11 Cette pompe ne fonctionne que sur le courant alternatif de 115 volts et elle est équipée d un cordon électrique approuvé à 3 conducteurs muni d une fiche à 3 broches dont une de mise à la terre Tension dangereuse Risque de secousses élec triques de brûlures voire de mort Pour réduire les risques de sec ousses électriques débrancher la fiche du cordon électrique de la pri...

Страница 8: ... élec triques de brûlures voire de mort La pompe est livrée avec un conducteur et une fiche de mise à la terre Pour réduire les risques de secousses électriques s assurer que la pompe n est branchée que dans un dispositif de mise à la terre adéquatement mis à la terre comme un tuyau d eau mis à la terre ou un chemin de câbles métallique adéquatement mis à la terre ou un système de fil de mise à la...

Страница 9: ...chons d air se forment dans la pompe la pompe continuera de fonctionner mais ne débitera pas d eau Un bouchon d air peut causer la surchauffe de la pompe et éventuellement sa panne Un petit trou est pratiqué dans le corps de cette pompe Se reporter à Figure 1 C est ce qu on appelle un clapet antibouchon d air Si on soupçonne qu il y a un bouchon d air introduire une épingle ou du nettoyant de tuya...

Страница 10: ...ur défectueux Remplacer l interrupteur à flotteur La pompe ne s arrête pas Interrupteur à flotteur défectueux Remplacer l interrupteur à flotteur Refoulement obstrué Déposer la pompe et la nettoyer ainsi que les tuyaux obstruction dans le tuyau Flotteur obstrué Enlever l obstruction La pompe fonctionne mais Tension de ligne basse Si la tension est inférieure à la tension minimum recommandée vérifi...

Страница 11: ...de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie Modèles SD106 SD107 90 jours Modèles SDAS3 SDVS3 SDSU25 SD CUST 2 ans Modèles SDAS5 3 ans Réservoir préchargé de système d eau 5 ans Pompe d eaux d égou...

Страница 12: ... 10 Cuando realice el cableado de una bomba de accionamiento eléctri co cumpla con todos los códigos de electricidad y seguridad que correspondan 11 Este equipo se debe usar solamente con 115 voltios y viene equipa do con un cordón aprobado de 3 conductores y un enchufe de 3 clavijas con conexión a tierra Tensión peligrosa Puede provocar choque que madura o muerte Para reducir el peligro de choque...

Страница 13: ...te en el tomacor riente y el enchufe de la bomba se inserta en el extremo opuesto del enchufe del interruptor Tensión peligrosa Puede provocar choques que maduras o muerte La bomba viene provista de un conductor de puesta a tierra y un enchufe de conexión a tierra Para reducir el riesgo de choque eléctrico verifique que se conecte solamente a un tomacorriente de puesta a tierra debidamente conecta...

Страница 14: ...ultar en un funcionamiento inadecuado una falla prematura e inundación BOLSAS DE AIRE Cuando una bomba tiene obturaciones por bolsas de aire funciona pero no mueve el agua Una bolsa de aire hará que la bomba se recaliente y falle Esta bomba tiene un pequeño orificio del lado de la caja de la bomba Ver figura 1 Es una válvula anti bolsas de aire Si sospecha que hay bolsas de aire inserte una aguja ...

Страница 15: ...e flotador La bomba arranca y se Interruptor de flotador defectuoso Reemplace el interruptor de flotador detiene con demasiada Descarga restringida Saque la bomba y limpie la bomba y la tubería frecuencia obstáculo en la tubería Flotador obstruido Elimine la obstrucción La bomba funciona pero Baja tensión de línea Si la tensión es inferior al mínimo recomendado verifique el tamaño de los descarga ...

Страница 16: ...cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bomba y el recibo de compra original a la tienda minorista Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminación Excepciones para la Garantía Limitada de Doce 12 Meses Producto Período de garantía Modelos SD106 SD107 90 días Modelos SDAS3 SDVS3 SDSU25 SD CUST 2 años...

Отзывы: