1.6 Protection / Display messages
DISPLAY
DESCRIPTION
rdY
Drive OK at STOP motor
run
Motor in movement
dIS
Drive DISABLE
ocur
Overcurrent Error
tenP
Overtemperature Error
uuoL
Undervoltage Error
ouoL
Overvoltage Error
rSt
Reset phase
0net
No connected
Drive is provided with protections against overtemperature, overvoltage, undervoltage, short-circuits among
outputs and among outputs and the positive power pole, no-phase motor connection.
If one of the mentioned conditions occurs, drive disables the power bridge and shows an error condition on
the display.
To restore overcurrent protection tou must restart the unit.
The decimal point to the left indicates the status RX, while the one on the right indicates the status of the
communication interface TX.