Net-8/5 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support. 
 
Important:  Fixtures on a serial data link must be daisy-chained in a single line. To comply with the  

EIA-485 standard, no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of fixtures on a DMX data link: 30 fixtures 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 
DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin. Ordercode 
FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m), 
FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m), 
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m). 

 

DAP Audio data cable FL08 DMX/AES-EBU, XLR/M 5-pin > XLR/F 5-pin. Ordercode FL08150 (1,5 m), 
FL083 (3 m), FL086 (6 m), FL0810 (10 m), FL0820 (20 m). 

 

DAP Audio DMX adapter: 5-pin/3-pin. Ordercode FLA29. 

 

DAP Audio DMX adapter: 3-pin/5-pin. Ordercode FLA30. 

 

DAP Audio DMX Terminator 3-pin. Ordercode FLA42. 

 

DAP Audio DMX Terminator 5-pin. Ordercode FLA43. 

 
DAP Audio PC Interface Cables

 

 

CAT-5 cable 7,6 mm Matte blue PVC. Ordercode FL55150 (1,5 m), FL553 (3 m), FL556 (6 m), FL5510 
(10 m), FL5515 (15 m), FL5520 (20 m). 

 

CAT-6 cable (recommended for best data transfer). Ordercode FL563 (3 m), FL566 (6 m), FL5610 
(10 m), FL5615 (15 m), FL5640 (40 m). 

 

 

Содержание Net-8/5

Страница 1: ...Net 8 5 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50810 MANUAL ENGLISH...

Страница 2: ...5 with Laptop PC 8 Setup Net 8 5 with Lighting controller 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Status Menu 11 Main Menu Options 12 1 Rename 12 2 Set DHCP 12 3 Set IP Address 13 4 Set...

Страница 3: ...ment includes Showtec Net 8 5 Schuko to Pro power connector power cable 1 3 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has t...

Страница 4: ...g Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltag...

Страница 5: ...than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endange...

Страница 6: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Страница 7: ...ata speed 8 universes DMX IN or OUT High speed network IN and OUT Input voltage 100 240 V AC 50 60 Hz Power consumption 20 W Connections 8 x 5 pin XLR IN OUT 2 x RJ45 IN OUT Pro power connector Blue I...

Страница 8: ...5 Check that all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply...

Страница 9: ...8 5 CAT5 CAT6 cable 04 Connect the laptop PC to the network switch CAT5 CAT6 cable 05 Supply electric power Plug the unit s mains power cord into a proper electric power supply socket Do not supply p...

Страница 10: ...ble 04 Connect the lighting controller to the network switch CAT5 CAT6 cable 05 Supply electric power Plug the unit s mains power cord into a proper electric power supply socket Do not supply power be...

Страница 11: ...ce DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X t...

Страница 12: ...DOWN buttons to navigate This menu shows the device s name which can be changed in the main menu For more information see 1 Rename on page 12 This menu shows which port is connected not connected X or...

Страница 13: ...n to select a letter The selected letter will be highlighted 05 Press the UP DOWN buttons to change the selected letter 06 Press the RIGHT button to confirm 07 Repeat steps 3 6 to edit the remaining l...

Страница 14: ...Press the UP DOWN buttons to select CANCEL to discard changes or ENTER to confirm the new IP address 09 Press the RIGHT button to confirm Note It is possible to change the IP address ONLY if DHCP see...

Страница 15: ...send the last changed value to the DMX port for each DMX channel in both universes PROTOCOL Choose ArtNet KlingNet or sACN FRAMERTE FS Set the DMX frames per second which will be sent Choose from 10 1...

Страница 16: ...on to confirm 7 Set LCD Backlight 01 Press the LEFT button to enter the main menu 02 Press the UP DOWN buttons to select SET LCD BACKLIGHT and press the RIGHT button to open the submenu The display sh...

Страница 17: ...4 input signals to the DMX ports 5 8 A network configuration needs to be carried out according to your network and your ArtNet receiver specifications ISOLATED MODE The node receives 8 separate ArtNe...

Страница 18: ...slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert t...

Страница 19: ...lity or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cab...

Страница 20: ...tions 8 x 5 pin XLR IN OUT 2 x RJ45 IN OUT Power connection Pro power connector Blue IN Control protocol ArtNET KlingNET sACN TCP IPv4 DMX 512 Electro mechanical effects 8 universes DMX IN OUT Support...

Страница 21: ...20 Order code 50810 Net 8 5 Dimensions...

Страница 22: ...21 Order code 50810 Net 8 5 Notes...

Страница 23: ...22 Order code 50810 Net 8 5...

Страница 24: ...2019 Showtec...

Отзывы: