16
Ordercode: 61000
FX Ice Jet
Maintenance
The Showtec FX Ice Jet requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture’s performance will be significantly reduced. Disconnect the mains power supply
and then wipe the cover with a damp cloth. Do not use alcohol or solvents. Do not immerse in liquid.
Keep connections clean. Disconnect electric power, then wipe the connections with a damp cloth.
Make sure that the connections are thoroughly dry before supplying electric power.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by an expert on regular basis in the course of an acceptance test.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01)
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
02)
There may not be any deformations on housings, fixations and installation spots.
03)
The electric power supply cables must not show any damages or material fatigue.
Troubleshooting
The FX Ice Jet is leaking
01)
Check if the coupling of the gas hose is connected properly to the coupling of the FX Ice Jet.
02)
Press it firmly if it is not entirely secured. This is only possible when there is no pressure on the hose.
03)
If the problem persists, consult the Showtec technical service.
Only a small smoke plume is visible when the CO
2
gas exits the FX Ice Jet
01)
Visibility can vary due to air humidity.
02)
The output will be more visible when there is high absolute air humidity.
No white smoke plume visible when the CO
2
gas exits the FX Ice Jet.
01)
Check if you have the right carbon dioxide cylinders.
02)
Connect bottles with liquid carbon dioxide and a dip pipe to the FX Ice Jet.
03)
In some cases the dip pipe may be broken. In that case, replace the carbon dioxide bottle with
another one and inform your gas supplier about the cylinder with a defective dip pipe.
Troubleshooting does not provide the solution
Always contact your local Showtec dealer in case of uncertainties, questions about the FX Ice Jet
performance or other issues with regard to the FX Ice Jet.