11
Ordercode: 61000
FX Ice Jet
Step 5
01)
Check if the gas valve on the CO
2
bottle is still in closed position.
02)
Check if the FX Ice Jet has been installed properly by connecting and disconnecting the electricity.
Note: If the system has been connected properly you will hear a clicking sound which is produced by the
opening and closing of the magnetic valve in the FX Ice Jet.
Step 6
01)
Connect the hose to the FX Ice Jet and secure it with an open-ended spanner (size 22).
Step 7
01)
Connect the other end of the hose to the CO
2
bottle (with a dip pipe).
02)
Turning it by hand should suffice! Use a wrench only if the coupling continues to leak.