3.4.1 Preparation
To obtain better scanning effects, please pay attention to the following details when scanning:
⚫
Markers shall be attached to models. If the device fails to catch markers, it will not emit laser lines.
-
Attach the markers evenly and randomly.
-
Four markers are required for the alignment at communal areas.
-
Ensure that the device’s ca
mera can scan at least 4 markers within the normal scanning range.
-
Please attach markers (smaller than 3mm) on the edges and/or at small facets of the model.
-
Do not attach the markers on the surface with high curvature.
-
Do not use damaged or incomplete markers.
-
Do not use greasy, dusty, or dirty markers.
-
The calibration board is only used for calibration.
Markers are attached correctly